... NLP65 Series Single, dual, and triple output Total Power 75W Input Voltage 264 Vac 120 - 370 Vdc Outputs: Single, dual, triple Special Features • Universal Input • 3” x 5” footprint • Low profile fits 1U applications • EN61000-3-2 compliance option (HCC) • Overvoltage and short circuit protection • with free air convection cooling • ...
... Output Power (Watts) 75W -40 °C to +85 °C 20 CFM FORCED AIR COOLING 65W Derate to 50% load See table 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70° 95% RH 10,000 feet max. 30,000 feet max. 2.4 G rms peak 516.4 Part IV Rev.12.12.08_102 NLP65 Series NATURAL 38W CONVECTION 32W COOLING ...
... NLP65-7620J 2 A 240 mV ±5. ±2.0% NLP65-7629J 3 A 150 mV ±5. ±2.0% NLP65-7605J 6.5 A 120 mV ±2.0% NLP65-7612J 5.3 A 150 mV ±2.0% NLP65-7615J 3.5 A 240 mV ±2.0% NLP65-7624J 11 Conducted emissions testing were performed using the standard EN55022 set- up with a stand alone NLP65 unit placed on a grounded metal plate with a line choke on the AC input and ground wires (i.e. the wires are looped through an EMI suppression toroid). For system compliance it is usually necessary to install an ‘off-the-shelf’ AC inlet with an integral line filter in the system chassis or to install a line choke on the input wires as close as possible to AC entry point of the system chasssis ...