MAX3205EATE+T Maxim Integrated Products, MAX3205EATE+T Datasheet - Page 6

IC ESD PROT DIFF 16-TQFN

MAX3205EATE+T

Manufacturer Part Number
MAX3205EATE+T
Description
IC ESD PROT DIFF 16-TQFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX3205EATE+T

Power (watts)
1.66W
Polarization
6 Channel Array - Unidirectional
Mounting Type
Surface Mount
Package / Case
16-TQFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Breakdown
-
Voltage - Reverse Standoff (typ)
-
ESD protection can be tested in various ways. The
MAX3205E/MAX3207E/MAX3208E are characterized
for protection to the following limits:
• ±15kV using the Human Body Model
• ±8kV using the Contact Discharge Method specified
• ±15kV using the IEC 61000-4-2 Air-Gap Discharge
ESD performance depends on a number of conditions.
Contact Maxim for a reliability report that documents
test setup, methodology, and results.
Figure 3 shows the Human Body Model, and Figure 4
shows the current waveform it generates when dis-
charged into a low impedance. This model consists of
a 100pF capacitor charged to the ESD voltage of inter-
est, which is then discharged into the device through a
1.5kΩ resistor.
The IEC 61000-4-2 standard covers ESD testing and
performance of finished equipment. The MAX3205E/
MAX3207E/MAX3208E help users design equipment
that meets Level 4 of IEC 61000-4-2. The main differ-
ence between tests done using the Human Body Model
Dual, Quad, and Hex High-Speed
Differential ESD-Protection ICs
Figure 3. Human Body ESD Test Model
6
in IEC 61000-4-2
Method
VOLTAGE
SOURCE
_______________________________________________________________________________________
HIGH-
DC
CHARGE-CURRENT-
LIMIT RESISTOR
1MΩ
R
C
100pF
C s
Human Body Model
STORAGE
CAPACITOR
1.5kΩ
RESISTANCE
±15kV ESD Protection
DISCHARGE
R
D
ESD Test Conditions
IEC 61000-4-2
DEVICE
UNDER
TEST
and IEC 61000-4-2 is higher peak current in IEC 61000-
4-2. Because series resistance is lower in the IEC
61000-4-2 ESD test model (Figure 5), the ESD-
withstand voltage measured to this standard is general-
ly lower than that measured using the Human Body
Model. Figure 2 shows the current waveform for the
±8kV, IEC 61000-4-2 Level 4, ESD Contact Discharge
test. The Air-Gap Discharge test involves approaching
the device with a charged probe. The Contact
Discharge method connects the probe to the device
before the probe is energized.
Figure 4. Human Body Model Current Waveform
Figure 5. IEC 61000-4-2 ESD Test Model
AMPERES
VOLTAGE
SOURCE
HIGH-
DC
I
P
36.8%
100%
90%
10%
CHARGE-CURRENT-
0
LIMIT RESISTOR
50MΩ TO 100MΩ
0
t
RL
R
C
150pF
C s
CURRENT WAVEFORM
STORAGE
CAPACITOR
TIME
RESISTANCE
DISCHARGE
330Ω
R
t
D
DL
I r
PEAK-TO-PEAK RINGING
(NOT DRAWN TO SCALE)
DEVICE
UNDER
TEST

Related parts for MAX3205EATE+T