Breaker Type
Hydraulic-Magnetic
Voltage
240VAC
Current - Trip (it)
13A
Number Of Poles
2
Actuator Type
Lever
Mounting Type
DIN Rail
Input Voltage Vac
240V
No. Of Poles
2
Current Rating
13A
Interrupting Capacity
10kA
Dielectric Strength
1.5kV
Trip Time
28s
Voltage Rating Vdc
0V
Trip Time Max
28sec
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Circuit Protection Solutions
Product Information

Related parts for 9926252013

9926252013 Summary of contents

Page 1

... Circuit Protection Solutions Product Information ...

Page 2

... Series—Mounting Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 CB4200 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 CB2200 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 CB9100 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Weidmuller’s DIN-rail mounted circuit breakers are avail- able for use in applications where circuit protection must be able to distinguish between circuit overloads and short circuits. Each circuit breaker has the ability to be reset without the need to change components ...

Page 3

... QL-2-13-DM-KM-02 3 9926252003 QL-2-13-DM-KM-03 4 9926252004 QL-2-13-DM-KM-04 5 9926252005 QL-2-13-DM-KM-05 6 9926252006 QL-2-13-DM-KM-06 7 9926252007 QL-2-13-DM-KM-07 8 9926252008 QL-2-13-DM-KM-08 10 9926252010 QL-2-13-DM-KM-10 13 9926252013 QL-2-13-DM-KM-13 15 9926252015 QL-2-13-DM-KM-15 16 9926252016 QL-2-13-DM-KM-16 20 9926252020 QL-2-13-DM-KM-20 25 9926252025 QL-2-13-DM-KM- (0.51) (1.02) 13 (0.51) 9926 Series–AC version Trip Curve 1000 Operating Characteristics Curve KM 100 Ambient Temperature 30°C ...

Page 4

... UL 489 listed, CSA C22.2 No. 5-02, CE, VDE *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately single pole unit so the current rating remains visible or approximately two pole unit) ...

Page 5

... UL 489A Listed, CE, VDE *Wire sizes: gauges specified are the minimum allow- able as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately single pole unit so the current rating remains visible or approximately two pole unit) ...

Page 6

... CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately single pole unit so the current rating remains visible or approximately two pole unit) ...

Page 7

... CSA C22.2 No. 235, CE Approved *Wire sizes: gauges specified are the minimum allow- able as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately single pole unit so the current rating remains visible or approximately two pole unit) ...

Page 8

– ...

Page 9

Mounting Options If the product is not vertically mounted in the normal DIN-rail mounting orientation, a rating factor must be applied. Figure 1 shows a diagram of the rating factor to apply. The published curves for these circuit breaker products ...

Page 10

... Circuit Breakers Thermal Magnetic Type • Rated from 0.05 to 16.0 amps • Available in single or double pole configurations • Features a tease free design to reduce contact damage • Offers push button trip/reset function • Trip free design means the breaker cannot be held closed against a fault • ...

Page 11

Technical Data † Rated voltage & current CSA Creepage resistance Dielectric strength Insulation resistance Interrupting capacity (VDE 0660, Part 101, P-2) Interrupting capacity; 4201 (UL 1077/EN 60934 PC1) Typical life rated current Shock Torque Vibration Temperature range ...

Page 12

... Circuit Breakers CB2200 Series Thermal Magnetic Type Single Pole • Rated from 0.1 to 32.0 amps • Available in single, double and triple pole configurations • Offers normally open (N/O) and normally closed (N/C) auxiliary contacts • Lever-switch trip/reset function • Mounts on 32mm or 35mm DIN-rail • ...

Page 13

CB2200 Series Dimensions in mm Technical Data † Rated voltage & current Auxiliary contacts Creepage resistance Dielectric strength Insulation resistance Interrupting capacity (VDE 0660, Part 101, P-2) Interrupting capacity (UL 1077/EN 60934 PC1) Typical life rated current ...

Page 14

... Circuit Breakers CB9100 Series Thermal Magnetic Type Single Pole • Rated from 0 amps • Available in single, double and triple pole configurations • Optional auxiliary contacts • Mounts on 35mm DIN-rail • UL and CSA approvals • CSA 277 VAC (1 pole) or 480 VAC (2 and 3 pole) • ...

Page 15

CB9100 Series Dimensions in mm Internal Wiring Diagram Technical Data Rated voltage & current UL 1077 277 V (1 pole) CSA C 22.2 No. 235 277 V (1 pole) VDE Creepage resistance PTI 250 to IEC 112 Insulation resistance >100 ...

Page 16

... Email: info1@weidmuller.ca Website: www.weidmuller.ca 10/07 • 5M • LIT0706 Singapore Weidmuller is the leading manufacturer of components Slovakia for electrical connection technology to transmit energy, Slovenia signals and data. The Weidmuller product portfolio South Africa ranges from terminal blocks, PCB connectors and South Korea ...

Related keywords