CLB-403-12C3N-B-A/40 Carling Technologies, CLB-403-12C3N-B-A/40 Datasheet

no-image

CLB-403-12C3N-B-A/40

Manufacturer Part Number
CLB-403-12C3N-B-A/40
Description
THERMO CIRCUIT BREAKER 40A
Manufacturer
Carling Technologies
Series
CLBr
Datasheet

Specifications of CLB-403-12C3N-B-A/40

Breaker Type
Thermal
Voltage
32VDC, 125/250VAC
Current - Trip (it)
40A
Number Of Poles
1
Actuator Type
Push to Reset
Mounting Type
Panel Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q2475204
Breaker must hold 100% of rated current and must trip at 150% and above, within the time limits shown in curve. Trip times specified at 25° ambient with no preloading.
1
NOTES:
All dimensions are in. [mm].
Tolerance ±.005 [.127] unless otherwise specified.
6
Time Delay
Dimensional Specifications
To adjust the breaker rating for ambient temperature multiply the breaker rating by the factor. ex.) 5 amp rating at 0°C: 5 x .67 = 3.3 amp. Select 3 amp rating.
Trip Time in Seconds
Trip Curves
www.carlingtech.com
CLB-Series Pushbutton Thermal Circuit Protector
Rating:
3 to 40A, 125-250VAC, 32VDC
Approvals:
UL, CUL, TUV, CE
UL1500/ISO8846 for ignition
protection/marine
Dielectric Strength:
2500 VAC/ 1 minute
Interrupting capacity:
2500 amps
Resettable overload capacity:
10x rated current
Insulation Resistance:
100M ohms
Operating Temperature:
-10°C to 60°C
Voltage drop:
< 0.25 V
Applications:
Household Appliances
Transportation
Marine
Power Strips
Medical Equipment
Audio Visual Equipment
Power Supplies

Related parts for CLB-403-12C3N-B-A/40

CLB-403-12C3N-B-A/40 Summary of contents

Page 1

... To adjust the breaker rating for ambient temperature multiply the breaker rating by the factor. ex.) 5 amp rating at 0° .67 = 3.3 amp. Select 3 amp rating. Dimensional Specifications NOTES: All dimensions are in. [mm]. Tolerance ±.005 [.127] unless otherwise specified. 6 CLB-Series Pushbutton Thermal Circuit Protector Rating 40A, 125-250VAC, 32VDC Approvals: UL, CUL, TUV, CE UL1500/ISO8846 for ignition ...

Page 2

... Type A B Type B C Type C D Type D E Type E F Type F 10 BUTTON MARKING (IF BLANK, NO MARKING amp amp amp amp amp amp CLB-Series Pushbutton Thermal Circuit Protector - Mounting Bushing Mounting Indicator Hole Type Nut Plate amp amp amp amp All indicator plates are marked “circuit breaker press to reset”. ...