85107A1214S5016 Souriau Connection Technology, 85107A1214S5016 Datasheet - Page 51

no-image

85107A1214S5016

Manufacturer Part Number
85107A1214S5016
Description
CONN RCPT 14POS JAM NUT W/SCKT
Manufacturer
Souriau Connection Technology
Series
Military, MIL-DTL-26482 G Series I, 851r
Datasheets

Specifications of 85107A1214S5016

Connector Type
Receptacle, Female Sockets
Number Of Positions
14
Shell Size - Insert
12-14
Mounting Type
Panel Mount, Bulkhead; Through Hole
Termination
Solder
Fastening Type
Bayonet Lock
Orientation
N (Normal)
Shell Material, Finish
Olive Drab Cadmium Plated
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Features
-
Ingress Protection
-
Shell Size, Military
-
Other names
S85107A1214S5016
851
Notice de câblage / Wiring instructions
Préparation des câbles / cable preparation
Contacts à sertir
Dénudage
• Apporter le plus grand soin à cette
• Afin de conserver toutes les caractéristiques
• Taux de remplissage conseillé :
• Contacts de taille 20 pour les câbles de :
• Contacts de taille 16, dénuder le câble sur
Raccordement câbles-
contacts
• Enfiler le câble dans le fût du contact et s’as-
Utilisation de l’embout
réducteur
• Contacts de taille 20, si le câble a une
• Contacts de taille 16, embout réducteur : réf.
opération. Utiliser une pince à dénuder
appropriée à la section du câble et en par-
fait état.
d’étanchéité du connecteur et permettre un
câblage rationnel, les fils doivent avoir les
dimensions ci-dessous :
6 mm.
surer que les brins du câble sont apparents
dans le trou de visite.
section inférieure à 0,21 mm
pensable d’intercaler un embout réducteur
: réf. 8500-781.
8500-1985, si le câble a une section égale
à 0,60 mm
- 050 % Ø maxi
- 050 % Ø mini
- 100 % Ø moyen
- Ø sur gaine ≤ à 2 mm, dénuder sur une
- Ø sur gaine > à 2 mm, dénuder sur une
longueur de 4,5 mm
longueur de 7 mm.
Taille des
contacts
20
16
2
.
1.20
1.60
min.
Ø sur gaine
contact / contact
2
, il est indis-
max.
2.80
2.1 1
Crimp contacts
Stripping
• This operation should be carried out with
• In order to maintain the connector’s excellent
• Recommended loading :
• Size 20 contacts for cables :
• Size 1 6 contacts, strip the cable to a length
Cable-contact assembly
• Insert the wire into the crimp barrel and
Reducing sleeve
• If a wire with a cross sectional area of
• Wires of cross sectional area of 0.6 mm
embout / sleeve
great care. Use stripping pliers which are in
good condition and which are designed for
use with the size of wire being stripped.
sealing characteristics and, at the same time,
meet the highest cabling standards the wires
should have the following external sheath
dimensions :
of 6 mm.
ensure that it has penetrated correctly by
checking that it may be seen through the
lateral hole in the barrel.
less than 0.21 mm
may be used with size 1 6 contacts by using a
reducing sleeve, ref. 8500-1 985.
- 050 % with max. diam. wires
- 050 % with min. diam. wires
- 100 % with medium size wires.
contact, it will be necessary to use a reducing
sleeve : ref. 8500-781.
- when Ø over insulation ≤ 2 mm strip to a
- when Ø over insulation > 2 mm strip to a
4.5 mm length
7-mm length.
Contacts
size
20
1 6
câble / cable
2
51
1.20
1.60
min.
is used with a size 20
Ø over sheath
max.
2.80
2.1 1
2

Related parts for 85107A1214S5016