3578 Cooper/Bussmann, 3578 Datasheet

no-image

3578

Manufacturer Part Number
3578
Description
FUSEBLOCK ACK 140-200 STUD MNT
Manufacturer
Cooper/Bussmann
Type
Blockr
Datasheet

Specifications of 3578

Fuse Size
ACK
Number Of Circuits
1
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Current Rating
15 Amps
Voltage Rating
500 Volts
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current Rating
-
Voltage
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
3578C

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
35787
Manufacturer:
tyco
Quantity:
35 000
Part Number:
35787
Manufacturer:
TE
Quantity:
35 000
Part Number:
3578AM
Manufacturer:
NS/国半
Quantity:
20 000
Catalog Symbol: ACK
Ampere Rating: 10 to 400 Amperes
Voltage Rating: 130 Volts DC or less
Agency Approvals:
U.L. Recognized (15-300A), Guide JFHR2, File E56412
Electrical Ratings (Catalog Symbol, Amperes and Voltage)
ACK-10
ACK-15
ACK-20
ACK-25
ACK-30
ACK-35
Test Specifications
Fuse
ACK
*Approximately.
General Information:
• These fuses avoid needless openings from starting currents or
• A fuse link which operates only on very high overloads or
• Thermal cutout functions on low overloads – the thermal
• This long time-lag also makes it unnecessary to use extra
Fuseblocks
Catalog
Number
ACK 10-30
ACK 35-60
ACK 70-100
Stud-Mounted Fuses
The only controlled copy of this BIF document is the electronic read-only version located on the
Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This
bulletin is intended to clearly present comprehensive product data and provide technical infor-
mation that will help the end user with design applications. Bussmann reserves the right, without
notice, to change design or construction of any products and to discontinue or limit distribution
of any products. Bussmann also reserves the right to change or update, without notice, any
technical information contained in this bulletin. Once a product has been selected, it should be
tested by the user in all possible applications.
12-17-98
SB98107
surges.
short-circuits.
cutout cannot operate quickly at any load, hence long time-
lag is obtained on high overloads of short duration.
large size or over-size fuses.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact
Bussmann Application Engineering at 314-527-1270 for more information.
130V
130V
130V
130V
130V
130V
Rev. A
ACK-40
ACK-50
ACK-60
ACK-70
ACK-75
ACK-80
Block
Number
4228
3411
2322
(10-100): 130 Vdc, (120-200): 72 Vdc,
(225-300): 48 Vdc
Load
200%
300%
500%
130V
130V
130V
130V
130V
130V
ACK-100
ACK-120
ACK-140
ACK-150
ACK-160
ACK-175
Catalog
Number
ACK 120-200
ACK 225-400
Opening Time
100 Seconds*
35 Seconds*
13 Seconds*
130V
72V
72V
72V
72V
72V
ACK-200
ACK-225
ACK-250
ACK-300
ACK-400
Block
Number
3569
3578
72V
80V
80V
80V
80V
Dimensional Data
Time-Current Characteristics–Total Clear
Catalog
Symbol
ACK 10–30
ACK 35–60
ACK 70–100
ACK 120–200
ACK 225–400
Note: 10-60 amp fuses use brass terminals and ferrules.
C
100
.01
10
.1
1
D
70-400 amp fuses use copper terminals and ferrules.
A
2.5∑
(63.5)
3.0∑
(76.20)
3.5∑
(88.90)
3.750∑
(95.25)
3.750∑
(95.25)
(± 0.79mm)
(± 0.031")
CURRENT IN AMPERES
B
.375∑
(9.53)
.470∑
(11.94) (17.40)
.547∑
(13.89) (19.05)
.750∑
(19.05) (19.05)
.610∑
(15.49) (19.05)
A
Dimensions in Inches and (mm)
C
.500∑
(12.70)
.685∑
.750∑
.750∑
.750∑
B
All other tolerances
D
.250∑
(6.35)
.344∑
(8.74)
.312∑
(7.92)
.375∑
(9.52)
.312∑
(7.92)
E
E
.557∑
14.15)
.812∑
(20.63)
1.062∑
(26.98)
1.062∑
(26.98)
1.062∑
(1.062)
Bussmann
AMPERE
RATING
G
F
(± 0.13) inches
F
.588∑
(14.94)
.860∑
(21.84)
1.125∑
(28.58)
1.15∑
(29.21)
1.125∑
(28.58)
(± 0.005) mm
BIF Doc #1040
Form No. ACK
ACK
Page 1 of 1
G
.031∑
(0.79)
.051∑
(1.30)
.050∑
(1.27)
.050∑
(1.27)
.050∑
(1.27)
®

Related parts for 3578

Related keywords