MGDS2-00003 Tyco Electronics, MGDS2-00003 Datasheet - Page 3

no-image

MGDS2-00003

Manufacturer Part Number
MGDS2-00003
Description
INDUCTOR 10UH 1.2A 20% 1137
Manufacturer
Tyco Electronics
Series
MGDS2r
Type
Drum Corer
Datasheet

Specifications of MGDS2-00003

Inductance
10µH
Current
1.2A
Current - Saturation
1.2A
Tolerance
±20%
Shielding
Shielded
Dc Resistance (dcr)
165 mOhm Max
Package / Case
0.421" L x 0.323" W x 0.146" H (10.70mm x 8.20mm x 3.70mm)
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 85°C
Frequency - Test
100kHz
Applications
General Purpose
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Q @ Freq
-
Self Resonant Freq
-
Current - Temperature Rise
-
Environmental
General
Other
Static Humidity
Storage Life
Moisture Resistance
Temperature Cycle
Temperature Shock
Range
Operating
Flammability
Vibration
Mechanical Shock
Solderability
Component Adhesion
Resistance to Solvent
Load Life
Item
For Print Distribution to Customers
After exposure part remains within
specified electrical parameters for L,
Q and DCR.
After exposure part remains within
specified electrical parameters for L,
Q and DCR.
After exposure, part shall not
have a shorted or open winding.
After exposure part remains
within specified electrical
parameters for L, Q and DCR.
After exposure part remains
within specified electrical
parameters for L, Q and DCR.
-40°C to +85°C
-40°C to +85°C
IEC 695-2-2
After exposure part remains
within specified electrical
parameters for L, Q and DCR.
After exposure part remains
within specified electrical
parameters for L, Q and DCR.
Wetting shall cover 90% minimum of
4 pounds
No sign of degradation in
appearance or marking detail.
After exposure, part shall not
have a shorted or open winding.
Specification
Expose parts to an environment of +50°C with 90 to 95% R.H. for
100 hours. After exposure, allow parts to dry for 2 hours before
measurements are taken.
Subject parts to an environment of +50°C 90 to 100% R.H. for 46 to
50 hours. After exposure, allow parts to dry for 2 hours before
measurements are taken.
Per MIL-STD 202 Method 106, ten 24 hour cycles at +25°C to
+65°C at 80 to 95% R.H. During any of the first 9 cycles, inductors
are revolved from the chamber and exposed to -10°C for 3 hours.
Allow parts to dry for 2 hours before measurements are taken.
10 cycles (Air to Air) 1 cycle shall consist of:
30 minutes exposure to +85°C
30 minutes exposure to -40°C
Allow 20 minutes transition between extremes.
10 cycles (Air to Air) 1 cycle shall consist of:
30 minutes exposure to -45°C
30 minutes exposure to +125°C
15 seconds maximum transition between temperatures
Withstands needle-flame test
Inductors shall be randomly vibrated per NAVMAT P9492
profile. Samples shall be subjected to 0.04G/Hz for a
minimum of 15 minutes per axis, for each of the three axes.
Test per MIL-STD 202 method 213 test condition A, test
mounted samples 3 axes, 6 times, totaling 18 shocks.
(50Gs, 11ms, half-sine).
Dip pads in RMA flux, 63/37 solder (Sn/Pb) at 232°C for 5 seconds
Withstands 3 minutes forced spray Freon TMS
Parts to be stored at 110°C for 1000 hours with rated current
applied. Parts to be tested at: start, 500 and 1000 hours. Allow
2 hours at room temperature before testing.
Apply and measure force with a digital force gauge set.
Withstands 6 minutes of alcohol.
Test Method/Condition
MGDS2
Series
Sheet 3 of 3
Revision
A0