TCF30 Cooper/Bussmann, TCF30 Datasheet

FUSE DUAL ELEMENT 30A 600V

TCF30

Manufacturer Part Number
TCF30
Description
FUSE DUAL ELEMENT 30A 600V
Manufacturer
Cooper/Bussmann
Series
CUBEFuse™ TCFr
Datasheets

Specifications of TCF30

Fuse Type
Slow Blow, Time Lag
Voltage - Rated
600VAC, 300VDC
Current
30A
Package / Case
Blade Module
Size / Dimension
1.880" L x 0.750" W x 1.000" H (47.75mm x 19.05mm x 25.40mm)
Mounting Type
Holder
Operating Temperature
-10°C ~ 65°C
Voltage Rating Vdc
300V
Voltage Rating Vac
600V
Fuse Current
30A
Blow Characteristic
Time Delay
Fuse Body Material
Glass Filled PES
Fuse Size Imperial
1.88 X 0.75 X 1"
Color
-
Dc Cold Resistance
-
Melting I²t
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Low-Peak
Finger-Safe, Dual-Element, Time-Delay Class J Performance Fuse, 1-100A, 600Vac/300Vdc
Catalog Symbols: TCF_ Indicating fuse (6-100A)
Dual-Element, Time-Delay Fuse: 10 Seconds Minimum Operating Time at
500% Rated Current
Ampere Rating: 1 to 100A
Voltage Rating: 600Vac/300Vdc
Interrupting Rating: 300kA RMS Sym. (UL)
Agency Information:
• UL Listed Special Purpose Fuse: Guide JFHR, File E56412
• CSA Certified Fuse: Class 1422- 02, File 53787
• CE compliance for the European Union low voltage directive
Other Ratings/Specifications:
Watts Loss at rated current: TCF30: 3.99W
Operating and Storage Temperature Range: 14 to 149°F(-10 to 65°C)
Material Specifications:
• Case: Glass filled PES (Polyethersulfone)
• Terminals: Copper alloy
• Terminal plating: Electroless tin
• Indicator lens: PES (Polyethersulfone)
• Indicator: Energetic chemical
Carton Quantity and Weight
0309
Amp
Rating
TCF1-30A
TCF35-60A
TCF70-100A
(indicating version only)
70-100A Case Size
BU-SB09230
Carton Weight Per Carton
Qty.
12
12
6
TCF_RN Non-indicating fuse (1-100A)
®
200kA RMS Sym. (CSA)
100kA DC (UL & CSA)
CUBEFuse
1.39
1.42
1.74
lbs
35-60A Case Size
TCF60: 6.23W
TCF100: 9.51W
0.63
0.65
0.79
kg
®
With and Without Indication
1-30A Case Size
TCFH_N 100, 60 & 30A Holders.
CUBEFuse Holders, Disconnects and Safety Switch
The CUBEfuse is used in the following Cooper Bussmann
Data Sheet 9007
CCP_CF 1-, 2- & 3-Pole
Catalog Numbers (amp rating)
Features and Product Benefits
• The world’s first finger-safe power fuse system.
• Smallest footprint of any class fuse including Class J, CC, T and RK.
• Meets Class J time-delay electrical performance requirements.
• Available with and without open fuse indication to meet every customer
• The indicating version features easyI D™ open fuse technology for faster
• Faster response to damaging faults to help reduce destructive thermal and
• True dual-element fuse construction with a minimum of 10 seconds time-
• Long time-delay minimizes nuisance circuit openings due to temporary
• High interrupting rating to safely interrupt faults up to 300kA.
• No venting of arc or molten metal and gases during opening.
• Robust cycling and inrush current withstand.
• Low let-through currents under fault conditions.
• Provides Type 2 “No Damage” protection for IEC motors starters when
• Easy selective coordination with any other Cooper Bussmann
switched disconnects
Indicating CUBEFuse
TCF6
TCF30
TCF70
Non-Indicating CUBEFuse
TCF1RN
TCF20RN TCF25RN
TCF50RN TCF60RN
Data Sheet 1157
requirement.
troubleshooting and reduced downtime.
magnetic forces.
delay at 500% of rating.
overloads and transient surges.
properly sized.
Class L, J and RK1 fuse with simple 2:1 amp ration between upstream and
downstream fuses.
Page 1 of 2
TCF3RN
TCF10
TCF35
TCF80
CCPB 1-, 2- & 3-Pole disconnects for
TCF30RN
TCF70RN
TCF6RN
the Quik-Spec™ Coordination
Panelboard. Data Sheet 1160
TCF15
TCF40
TCF90
Data Sheet 9000
®
products.
TCF17-
TCF10RN
TCF35RN
TCF80RN
TCF100
TCF45
1
/
2
TCF15RN
TCF40RN
TCF90RN
TCF20
TCF50
Switch disconnect (optional
window). Data Sheet 1156
CF_ Quik-Spec™ Safety
®
TCF17-
TCF100RN
Low-Peak
TCF45RN
TCF25
TCF60
1
/
2
RN
®

Related parts for TCF30

TCF30 Summary of contents

Page 1

... UL Listed Special Purpose Fuse: Guide JFHR, File E56412 • CSA Certified Fuse: Class 1422- 02, File 53787 • CE compliance for the European Union low voltage directive Other Ratings/Specifications: Watts Loss at rated current: TCF30: 3.99W TCF60: 6.23W TCF100: 9.51W Operating and Storage Temperature Range 149°F(-10 to 65°C) Material Specifications: • ...

Page 2

TCF_ and TCF_RN Dimensions – in (mm) Time-Current Characteristic Curves–Average Melt The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition ...

Related keywords