CMR-5054TB-A CUI Inc, CMR-5054TB-A Datasheet - Page 3

MIC CONDENSER ELECT N/C -54DB

CMR-5054TB-A

Manufacturer Part Number
CMR-5054TB-A
Description
MIC CONDENSER ELECT N/C -54DB
Manufacturer
CUI Inc
Type
Electret Condenserr
Datasheet

Specifications of CMR-5054TB-A

Sensitivity
-54dB ±3dB
Voltage - Rated
2 ~ 10V
Current
500µA
Size / Dimension
Circular - 6mm Dia x 5mm H
S/n Ratio
56dB
Impedance
2.2K Ohm
Frequency
100Hz ~ 10kHz
Termination
Solder Pads
Direction
Noise Cancelling
Port Location
Top
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Filter Type
-
Other names
102-1730
PART NUMBER: CMR-5054TB-A
TEST CONDITIONS
standard test condition
judgement test condition
MECHANICAL CHARACTERISTICS
item
soldering heat resistance
PCB wire pull strength
vibration
drop test
ENVIRONMENT TEST
item
high temp. test
low temp. test
humidity test
temp. cycle test
20050 SW 112
th
Ave. Tualatin, Oregon 97062
a) temperature: +5 ~ +35°C
a) temperature: +25 ±2°C
test condition
Soldering iron of 270 ±5°C should be placed on
the terminal for 2 ±0.5 seconds.
The pull force will be applied to double lead
wire:
Horizontal 4.9N (0.5kg) for 30 seconds
The part will be measured after applying a
vibration amplitude of 1.5 mm with 10 to 55 Hz
band of vibration frequency to each of the
3 perpendicular directions for 2 hours.
The part will be dropped from a height of
1 m onto a 20 mm thick wooden board 3 times
in 3 axes (X, Y, Z) for a total of 9 drops.
test condition
After being placed in a chamber at +70°C for
72 hours.
After being placed in a chamber at -20°C for
72 hours.
After being placed in a chamber at +40°C and
90±5% relative humidity for 240 hours.
The part shall be subjected to 10 cycles. One
cycle will consist of:
phone 503.612.2300 fax 503.612.2383
DESCRIPTION: electret condenser microphone
b) humidity: 45 - 85%
b) humidity: 60 - 70%
evaluation standard
evaluation standard
No interference in operation.
No damage or cutting off.
After any tests, the sensitivity
should be within ±3dB compared
to the initial measurement.
The part will be measured after
being placed at +25°C for 6
hours. After any tests, the
sensitivity should be within ±3dB
compared to the initial
measurement.
c) pressure: 860-1060 mbar
c) pressure: 860-1060 mbar
page
date
06/2008
3 of 4

Related parts for CMR-5054TB-A