75EET Cooper/Bussmann, 75EET Datasheet

FUSE 75A 660V TYPE T

75EET

Manufacturer Part Number
75EET
Description
FUSE 75A 660V TYPE T
Manufacturer
Cooper/Bussmann
Series
EETr
Datasheet

Specifications of 75EET

Voltage - Rated
690VAC
Current
75A
Package / Case
Bolt Mount
Size / Dimension
3.701" L x 1.457" W x 0.748" H (94.00mm x 37.00mm x 19.00mm)
Mounting Type
Bolt Mount
Melting I²t
4400
Voltage Rating Vdc
690V
Voltage Rating Vac
690V
Fuse Current
75A
Length/height, External
93.7mm
Voltage Ac
690V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating Temperature
-
Color
-
Fuse Type
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
“F” Range
This is a superior design of fuses in the same physical
package as the “T” range.
Equivalent Ratings
This table shows the suggested equivalent ratings to
replace a “T” with an “F”.
Because of the new design technology it has been possible
to obtain the equivalent energy let-through I
amp rated fuse hence reducing the possibility of premature
operation.
This table gives a range of suggested acceptable new “F”
type to replace the earlier “T” type.
To upgrade your protection to the new “F” series select a
fuse rating within the range shown that suits your circuit
inrush requirements. You will still have the same or better
protection of your semiconductor devices.
It should be remembered that to protect devices we must
consider the energy let-through of the selected fuse. The
label amp rating will relate to the full load current and the
circuit inrush amps.
The suggested replacements are based on:
This gives enhanced reliability due to the use of a higher
current rated fuse which avoids nuisance operation and still
gives improved short-circuit protection.
84
The Edison British Style semiconductor protection fuses
include a 660VAC line utilizing new filler technology. These
new fuses have greatly reduced peak let-through current
and energy under fault conditions and hence extend fuse
protection capability. They can be recognized by the letter
“F” in their catalog number. Application and technical data
for these 660VAC “F” fuses and the original line of 240VAC
British “T” type fuses are presented on the following pages.
a. Similar surge withstand to normal circuit overloads.
b. Lower total I
2
t let-through.
2
t with a higher
Replacement Table — “T” to “F” (660V)
Earlier
“T” Range
6CT
10CT
12CT
16CT
20CT
25ET
32ET
35ET
40ET
45ET
56ET
63ET
80ET
65EET
75EET
90EET
110EET
140EET
160EET
160MT
180MT
200MT
250MT
280MT
315MT
355MT
180MMT
200MMT
225MMT
280MMT
315MMT
355MMT
400MMT
450MMT
500MMT
560MMT
630MMT
710MMT
SEMICONDUCTOR PROTECTION FUSES
New “F” Range
Lowest
Rating
6FC
10FC
12FC
16FC
20FC
35FE
35FE
40FE
45FE
63FE
63FE
80FE
140FEE
160FEE
200FM
225FM
250FM
280FM
315FM
350FM
350FM
350MT
180FM
200FM
225FM
280FM
315FM
350FM
500FMM
550FMM
630FMM
700FMM
700FMM
700FMM
BRITISH STYLE–
Highest
Rating
6FC
10FC
12FC
16FC
20FC
35FE
40FE
45FE
50FE
63FE
71FE
80FE
90FE
100FE
100FEE
120FEE
140FEE
160FEE
180FEE
200FEE
180FM
200FM
225FM
250FM
280FM
315FM
350FM
350FM
350FM
180FM
200FM
225FM
280FM
315FM
350FM
400FMM
450FMM
500FMM
550FMM
630FMM
700FMM
700FMM
700FMM

Related parts for 75EET

75EET Summary of contents

Page 1

... Range 6CT 10CT 12CT 16CT 20CT 25ET 32ET 35ET 40ET 45ET 56ET 63ET – – 80ET 65EET t with a higher 2 75EET 90EET 110EET – 140EET – 160EET – 160MT 180MT 200MT – 250MT 280MT 315MT 355MT 180MMT 200MMT 225MMT 280MMT ...

Page 2

... 71FE 210 600 950 80FE 250 900 1500 90FE 360 1300 2100 100FE 470 1800 2800 65EET 210 2000 3000 75EET 420 2600 4400 90EET 490 3000 4500 100FEE 400 1600 2400 120FEE 540 1900 3100 140FEE 850 2500 3800 160FEE ...

Page 3

... Interrupting rating 200kA RMS Symmetrical. • Watts loss provided at rated current. • All fuses above have been tested to 318VAC. • These fuses meet the requirements Part 4 and IEC 269-4 • UL Recognition on LET and LMT. Others pending – Consult Edison. 86 SEMICONDUCTOR PROTECTION FUSES ...

Page 4

... Type 74.6 64.3 LCT & 63.5 LET 56 41.8 FEE & EET 113 80-85 LMT 84 59 FMM 113 80-85 LMMT & LCT FM & LMT SEMICONDUCTOR PROTECTION FUSES 54.8 8.7 8.7 28 8.4 8.7 48 17.7 19.1 26.2 17.7 19 41 FE, ET & LET BRITISH STYLE– ...

Page 5

... CURRENT IN AMPERES 660V Time-Current Curves FC (6-20A) FE (35-100A) FM (180-350A) 88 SEMICONDUCTOR PROTECTION FUSES AMPERE RATING 660V Time-Current Curves FEE (100-200A) FMM (400-700A CURRENT IN AMPERES BRITISH STYLE– AMPERE RATING ...

Page 6

... CURRENT IN AMPERES 240V Time-Current Curves LCT (6-20A) LET (25-180A) LMMT (400-900A) SEMICONDUCTOR PROTECTION FUSES AMPERE RATING 240V Time-Current Curves LMT (160-450A .01 .004 CURRENT IN AMPERES BRITISH STYLE– AMPERE RATING 89 ...

Page 7

Indicator System Trip-Indicators Trip-indicators are available for use in parallel with the main fuse. They can either be attached to the associated fuse or mounted separately in panel mounted fuse clips, reference CL1. A push-on adapter and microswitch attachment is ...

Related keywords