DQ1260-100M Tyco Electronics, DQ1260-100M Datasheet - Page 3

no-image

DQ1260-100M

Manufacturer Part Number
DQ1260-100M
Description
INDUCTOR 10UH 4A 20% 1260
Manufacturer
Tyco Electronics
Series
DQ1260r
Datasheet

Specifications of DQ1260-100M

Inductance
10µH
Current
4A
Current - Saturation
4A
Tolerance
±20%
Shielding
Shielded
Dc Resistance (dcr)
25 mOhm Max
Package / Case
0.504" L x 0.504" W x 0.236" H (12.80mm x 12.80mm x 6.00mm)
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 85°C
Frequency - Test
100kHz
Applications
EMI Filter
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Q @ Freq
-
Self Resonant Freq
-
Current - Temperature Rise
-
Other names
436-1048-2
Environmental
General
Other
Chemical
Static Humidity
Storage Life
Temperature Cycle
Temperature Shock
IR Reflow
Storage Temperature
Range
Operating Temperature
Range
Flammability
Vibration
Mechanical Shock
Solderability
Component Adhesion
(Push Test)
Resistance to Solvent
Ionic Contamination
Item
For Print Distribution to Customers
After exposure part remains within
specified electrical parameters for
L, Q and DCR.
After exposure part remains within
specified electrical parameters for
L, Q and DCR.
After exposure part remains within
specified electrical parameters for
L, Q and DCR.
After exposure part remains within
specified electrical parameters for
L, Q and DCR.
5-8 seconds at 240°C max.
-40°C to +85°C
-40°C to +85°C
IEC 695-2-2
After exposure part remains within
specified electrical parameters for
L, Q and DCR.
After exposure part remains within
specified electrical parameters for
L, Q and DCR.
Wetting shall cover 90% minimum of
each termination
Component shall withstand 6 lb. push
force minimum without delaminating
from mounting surface.
Conductivity:
pH:
Chlorides:
Sodium:
Potassium:
Specification
Precondition at 25°C for 60 minutes. Expose parts to an
environment of +40°C with 90 to 95% R.H. for 240 hours.
Subject parts to an environment of 85°C 85% R.H. for 168
hours. After exposure allow parts to dry for 4 hours before
measurements are taken.
10 cycles (Air to Air) 1 cycle shall consist of:
30 minutes exposure to +85°C
30 minutes exposure to -40°C
Allow 20 minutes transition between extremes.
10 cycles (Air to Air) 1 cycle shall consist of:
30 minutes exposure to -55°C
30 minutes exposure to +125°C
15 seconds maximum transition between temperatures
Ramped reflow in oven to 240°C +4%-0%. Post test parts shall
pass all electrical specifications after reflow. Parts shall not
show visible signs of solder flow or leakage from the part.
Withstands needle-flame test
1 cycle of 30 minutes of the following:
5 - 7 Hz constant displacement of 0.75 inches, 5 minutes
7 - 30 Hz constant acceleration of 1.5 Gs, 10 minutes
31 - 50 Hz constant displacement of 0.33 inches, 5 minutes
50 - 500 Hz constant acceleration of 1.2 Gs, 10 minutes
DQ6530 Series - 500 Gs per axis, 2 directions
DQ6545 Series - 500 Gs per axis, 2 directions
DQ7534 Series - 500 Gs per axis, 2 directions
DQ7545 Series - 500 Gs per axis, 2 directions
DQ1260 Series - 500 Gs per axis, 2 directions
DQ1280 Series - 500 Gs per axis, 2 directions
Dip pads in RMA
flux, 63/37 solder
(Sn/Pb) at 232°C for
5 seconds ±2
seconds.
Apply and measure force with a digital force gauge set.
Withstands 6 minutes of alcohol.
Withstands 3 minutes forced spray Freon TMS
11 µOhms/cm maximum
5.5 to 9
65 ppm maximum
20 ppm maximum
10 ppm maximum
Test Method/Condition
DQ SERIES
Series
Sheet 3 of 3
Revision
E