AT91SAM7S32B-MU Atmel, AT91SAM7S32B-MU Datasheet - Page 605

IC MCU ARM7 32KB FLASH 48-VQFN

AT91SAM7S32B-MU

Manufacturer Part Number
AT91SAM7S32B-MU
Description
IC MCU ARM7 32KB FLASH 48-VQFN
Manufacturer
Atmel
Series
AT91SAMr
Datasheet

Specifications of AT91SAM7S32B-MU

Core Processor
ARM7
Core Size
16/32-Bit
Speed
55MHz
Connectivity
I²C, SPI, SSC, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
21
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
48-VQFN Exposed Pad, 48-HVQFN, 48-SQFN, 48-DHVQFN
For Use With
AT91SAM-ICE - EMULATOR FOR AT91 ARM7/ARM9AT91SAM7S-EK - KIT EVAL FOR ARM AT91SAM7S
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
AT91SAM7S32B-MU
Quantity:
2 600
40.5.1.6
40.5.1.7
40.5.1.8
40.5.1.9
40.5.1.10
40.5.1.11
6175K–ATARM–30-Aug-10
ADC: GOVRE Bit is not Set when Disabling a Channel
ADC: EOC Set although Channel Disabled
ADC: Spurious Clear of EOC Flag
ADC: Sleep Mode
ADC: GOVRE Bit is not Set when Reading CDR
ADC: OVRE Flag Behavior
When reading CDRy (Channel Data Register y) at the same instant as an end of conversion on
channel “x” with the following conditions:
GOVRE should be set but is not.
None
When disabling channel “y” at the same instant as an end of conversion on channel “x”, EOC[x]
and DRDY being already active, GOVRE does not rise.
Note:
None
When the OVRE flag (on channel i) has been set but the related EOC status (of channel i) has
been cleared (by a read of CDRi or LCDR), reading the Status register at the same instant as an
end of conversion (causing the set of EOC status on channel i), does not lead to a reset of the
OVRE flag (on channel i) as expected.
None
If a channel is disabled while a conversion is running and if a read of CDR is performed at the
same time as an end of conversion of any channel occurs, the EOC of the channel with the con-
version running may rise (whereas it has been disabled).
Do not take into account the EOC of a disabled channel
If “x” and “y” are two successively converted channels and “z” is yet another enabled channel
(“z” being neither “x” nor “y”), reading CDR on channel “z” at the same instant as an end of con-
version on channel “y” automatically clears EOC[x] instead of EOC[z].
None.
If Sleep mode is activated while there is no activity (no conversion is being performed), it will
take effect only after a conversion occurs.
• EOC[x] already active,
• DRDY already active,
• GOVRE inactive,
• previous data stored in LCDR being neither data from channel “y”, nor data from channel “x”.
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround:
Problem Fix/Workaround
Problem Fix/Workaround
OVRE[x] rises as expected.
AT91SAM7S Series Preliminary
605