C8051T612-GQ Silicon Laboratories Inc, C8051T612-GQ Datasheet - Page 106

IC 8051 MCU 8K BYTE-PROG 32-LQFP

C8051T612-GQ

Manufacturer Part Number
C8051T612-GQ
Description
IC 8051 MCU 8K BYTE-PROG 32-LQFP
Manufacturer
Silicon Laboratories Inc
Series
C8051T61xr
Datasheets

Specifications of C8051T612-GQ

Program Memory Type
OTP
Program Memory Size
8KB (8K x 8)
Package / Case
32-LQFP
Core Processor
8051
Core Size
8-Bit
Speed
25MHz
Connectivity
SMBus (2-Wire/I²C), SPI, UART/USART
Peripherals
POR, PWM, Temp Sensor, WDT
Number Of I /o
29
Ram Size
1.25K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 3.6 V
Data Converters
A/D 21x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Processor Series
C8051T6x
Core
8051
Data Bus Width
8 bit
Data Ram Size
1.25 KB
Interface Type
I2C/SPI/UART
Maximum Clock Frequency
25 MHz
Number Of Programmable I/os
29
Number Of Timers
4
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Development Tools By Supplier
C8051FT610DK
Minimum Operating Temperature
- 40 C
On-chip Adc
21-ch x 10-bit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1439

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051T612-GQ
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
C8051T612-GQR
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
C8051T610/1/2/3/4/5/6/7
20. Oscillators and Clock Selection
C8051T610/1/2/3/4/5/6/7 devices include a programmable internal high-frequency oscillator and an exter-
nal oscillator drive circuit. The internal high-frequency oscillator can be enabled/disabled and calibrated
using the OSCICN and OSCICL registers, as shown in Figure 20.1. The system clock can be sourced by
the external oscillator circuit or the internal oscillator. The internal oscillator also offers a selectable post-
scaling feature.
OSCICL
OSCICN
RC Mode
VDD
EXTCLK
EN
Programmable
n
Internal Clock
Generator
SYSCLK
C Mode
Input
EXTCLK
EXTCLK
OSC
Circuit
CMOS Mode
EXTCLK
OSCXCN
CLKSEL
Figure 20.1. Oscillator Options
20.1. System Clock Selection
The CLKSL0 bit in register CLKSEL selects which oscillator source is used as the system clock. CLKSL0
must be set to 1 for the system clock to run from the external oscillator; however the external oscillator may
still clock certain peripherals (timers, PCA) when the internal oscillator is selected as the system clock. The
system clock may be switched on-the-fly between the internal oscillator and external oscillator, so long as
the selected clock source is enabled and running.
The internal high-frequency oscillator requires little start-up time and may be selected as the system clock
immediately following the register write which enables the oscillator. The external RC and C modes also
typically require no startup time.
106
Rev 1.0

Related parts for C8051T612-GQ