SAF-XC866-4FRI BC Infineon Technologies, SAF-XC866-4FRI BC Datasheet - Page 62

no-image

SAF-XC866-4FRI BC

Manufacturer Part Number
SAF-XC866-4FRI BC
Description
IC MCU 8BIT 16KB FLASH TSSOP-38
Manufacturer
Infineon Technologies
Series
XC8xxr
Datasheet

Specifications of SAF-XC866-4FRI BC

Core Processor
XC800
Core Size
8-Bit
Speed
86MHz
Connectivity
SSI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
19
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
768 x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
38-TSSOP
For Use With
MCBXC866 - BOARD EVAL FOR INFINEON XC86X
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Other names
FX8664FRIBCXT
SAF-XC866-4FRIBC
SAF-XC866-4FRIBCINTR
SAF-XC866-4FRIBCTR
SAF-XC866-4FRIBCTR
SAFXC8664FRIBCXT
SP000057470
The clock system provides three ways to generate the system clock:
PLL Base Mode
The system clock is derived from the VCO base (free running) frequency clock divided
by the K factor.
Prescaler Mode (VCO Bypass Operation)
In VCO bypass operation, the system clock is derived from the oscillator clock, divided
by the P and K factors.
PLL Mode
The system clock is derived from the oscillator clock, multiplied by the N factor, and
divided by the P and K factors. Both VCO bypass and PLL bypass must be inactive for
this PLL mode. The PLL mode is used during normal system operation. .
Table 3-1
selection.
Table 3-1
OSCDISC
0
0
1
1
Note: When oscillator clock is disconnected from PLL, the clock mode is PLL Base mode
System Frequency Selection
For the XC866, the values of P and K are fixed to “1” and “2”, respectively. In order to
obtain the required system frequency, f
for different oscillator inputs.
obtained for the different oscillator sources.
Data Sheet
regardless of the setting of VCOBYP bit.
shows the settings of bits OSCDISC and VCOBYP for different clock mode
Clock Mode Selection
VCOBYP
0
1
0
1
Table 21
f
f
SYS
SYS
f
SYS
=
=
=
provides examples on how f
f
f
sys
VCObase
OSC
f
Clock Working Modes
PLL Mode
Prescaler Mode
PLL Base Mode
PLL Base Mode
OSC
, the value of N can be selected by bit NDIV
58
×
×
-------------
P
-------------
P K
N
×
×
×
1
K
--- -
K
1
Functional Description
sys
= 80 MHz can be
V1.2, 2007-10
XC866

Related parts for SAF-XC866-4FRI BC