AD602AR Analog Devices Inc, AD602AR Datasheet - Page 5

no-image

AD602AR

Manufacturer Part Number
AD602AR
Description
IC AMP VGA DUAL LN 50MA 16SOIC
Manufacturer
Analog Devices Inc
Series
X-AMP®r
Datasheet

Specifications of AD602AR

Rohs Status
RoHS non-compliant
Amplifier Type
Variable Gain
Number Of Circuits
2
Slew Rate
275 V/µs
-3db Bandwidth
35MHz
Current - Input Bias
350nA
Current - Supply
11mA
Current - Output / Channel
50mA
Voltage - Supply, Single/dual (±)
±4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
16-SOIC (0.300", 7.5mm Width)
Output Type
-
Gain Bandwidth Product
-
Voltage - Input Offset
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD602AR
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD602AR/JR
Manufacturer:
AD
Quantity:
2 197
Part Number:
AD602ARZ
Manufacturer:
Analog Devices Inc
Quantity:
135
Part Number:
AD602ARZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD602ARZR7
Manufacturer:
NXP
Quantity:
6 997
ABSOLUTE MAXIMUM RATINGS
Table 2.
Parameter
Supply Voltage ±V
Input Voltages
Internal Power Dissipation
Operating Temperature Range
Storage Temperature Range
Lead Temperature (Soldering 60 sec)
θ
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
JA
Pin 1, Pin 8, Pin 9, Pin 16
Pin 2, Pin 3, Pin 6, Pin 7
Pin 4, Pin 5
J Grade
A Grade
S Grade
16-Lead PDIP
16-Lead SOIC_W
16-Lead CERDIP
S
Rating
±7.5 V
±V
±2 V continuous
±V
±V
600 mW
0°C to 70°C
−40°C to +85°C
−55°C to +125°C
−65°C to +150°C
300°C
85°C/W
100°C/W
120°C/W
S
S
S
for 10 ms
Rev. E | Page 5 of 28
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
AD600/AD602