S-80127BLMC-JEMT2G Seiko Instruments, S-80127BLMC-JEMT2G Datasheet - Page 17

no-image

S-80127BLMC-JEMT2G

Manufacturer Part Number
S-80127BLMC-JEMT2G
Description
IC VOLT DETECTOR 100MS SOT23-5
Manufacturer
Seiko Instruments
Type
Simple Reset/Power-On Resetr
Datasheet

Specifications of S-80127BLMC-JEMT2G

Number Of Voltages Monitored
1
Output
Push-Pull, Totem Pole
Reset
Active Low
Reset Timeout
65 ms Minimum
Voltage - Threshold
2.7V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
SOT-23-5, SC-74A, SOT-25
Output Type
Push-Pull
Undervoltage Threshold
2.7 V
Power-up Reset Delay (typ)
100 ms
Supply Voltage (min)
0.95 V
Supply Voltage (max)
10 V
Supply Current (typ)
1.5 uA
Operating Temperature Range
- 40 C to + 85 C
Mounting Style
SMD/SMT
Description/function
Open-drain and CMOS output,
Detection Range
2.7 V +/- 2 %
Internal Hysteresis
Yes
Manual Reset
No
Operating Supply Voltage
0.7 V to 10 V
Watchdog
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rev.4.0
(−V
(−V
Technical Terms
ULTRA-SMALL PACKAGE HIGH-PRECISION VOLTAGE DETECTOR WITH DELAY CIRCUIT (INTERNAL DELAY TIME SETTING)
DET
DET
1. Detection Voltage (–V
Remark Although the detection voltage and release voltage overlap in the range of 2.186 V to 2.244 V,
) Max.
) Min.
V
DD
_00
The detection voltage (–V
slightly among products of the same specification. The variation of detection voltage between the
specified minimum (–V
(Refer to Figure 14).
e.g. For the S-80122AN, the detection voltage lies in the range of 2.156 ≤ (–V
The release voltage (+V
slightly among products of the same specification. The variation of release voltages between the
specified minimum (+V
(Refer to Figure 15).
e.g. For the S-80122AN, the release voltage lies in the range of 2.186 ≤ (+V
Figure 14 Detection Voltage
OUT
+V
This means that some S-80122ANs have 2.156 V for –V
This means that some S-80122ANs have 2.186 V for +V
DET
is always larger than –V
DET
DET
DET
), Release Voltage (+V
DET
DET
) Min. and the maximum (–V
) Min. and the maximum (+V
Detection voltage
Detection voltage
range
) is a voltage at which the output turns to high. The release voltage varies
) is a voltage at which the output turns to low. The detection voltage varies
Seiko Instruments Inc.
DET
.
DET
(+V
)
(+V
Release voltage
DET
DET
DET
DET
) Max.
) Min.
) Max. is called the detection voltage range
) Max. is called the release voltage range
Figure 15 Release Voltage
DET
DET
and some have 2.244 V.
and some have 2.344 V.
DET
DET
V
) ≤ 2.344.
DD
) ≤ 2.244.
S-801 Series
OUT
Delay time
Release voltage
range
17