BA60BC0WT Rohm Semiconductor, BA60BC0WT Datasheet - Page 2

IC REG LDO 1A 6V SHTDN TO220FP-5

BA60BC0WT

Manufacturer Part Number
BA60BC0WT
Description
IC REG LDO 1A 6V SHTDN TO220FP-5
Manufacturer
Rohm Semiconductor
Datasheets

Specifications of BA60BC0WT

Regulator Topology
Positive Fixed
Voltage - Output
6V
Voltage - Input
Up to 16V
Voltage - Dropout (typical)
0.3V @ 500mA
Number Of Regulators
1
Current - Output
1A (Max)
Current - Limit (min)
1A
Operating Temperature
-40°C ~ 105°C
Mounting Type
Through Hole
Package / Case
TO-220-5 Full Pack (Straight Leads)
Number Of Outputs
1
Polarity
Positive
Input Voltage Max
16 V
Output Voltage
6 V
Output Type
Fixed
Dropout Voltage (max)
0.5 V at 500 mA
Output Current
1 A
Line Regulation
35 mV
Load Regulation
75 mV
Voltage Regulation Accuracy
2 %
Maximum Power Dissipation
2 W
Maximum Operating Temperature
+ 105 C
Mounting Style
Through Hole
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Absolute Maximum Ratings (Ta = 25°C)
Recommended Operating Conditions
Electrical Characteristics
© 2010 ROHM Co., Ltd. All rights reserved.
BA□□BC0 Series,BA□□BC0W Series,BA00BC0W Series
www.rohm.com
BA□□BC0FP/T/WFP/WT (−V5)
(Unless otherwise specified, Ta = 25°C; V
BA00BC0WFP/WT (−V5)/CP-V5
(Unless otherwise specified, Ta = 25°C, Vcc = 3.3 V, V
Output voltage
Shutdown circuit current
Minimum I/O voltage difference
Output current capacity
Input stability
Load stability
Temperature coefficient of
output voltage
Shutdown circuit current
Reference voltage
Minimum I/O voltage difference
Output current capacity
Input stability
Load stability
Temperature coefficient of output
voltage
Power supply voltage
Power
dissipation
Operating temperature range
Ambient storage temperature
Maximum junction temperature
Input power supply voltage
Input power supply voltage
Output current
Variable output voltage setting value
*1 Must not exceed Pd.
*2 Derated at 9.6mW/°C at Ta>25°C when mounted on a glass epoxy board (70 mm  70 mm  1.6 mm).
*3 Derated at 10.4mW/°C at Ta>25°C when mounted on a glass epoxy board (70 mm  70 mm  1.6 mm).
*4 Derated at 16mW/°C at Ta> 25°C
*5 When output voltage is 1.5 V, 1.8 V, or 2.5 V.
*6 When output voltage is 3.0 V or higher.
Vo (T): Set output voltage
*7 Vo = 1.5 V, 1.8 V, 2.5 V : Vcc = 3.3 V, Vo = 3.0 V, 3.3 V : Vcc = 5 V,
*8 Vo ≥ 3.3 V
*9 Change Vcc from 3.0 V to 6 V if 1.5 V ≤ Vo ≤ 2.5 V.
*10 Operation guaranteed
*11 VOUT = Vc  (R1 + R2) / R1 (V)
*12 Operation guaranteed
Vo = 5.0 V : Vcc : 8 V, Vo = 6.0 V : Vcc = 9 V, Vo = 8.0 V : Vcc = 11 V,
Vo = 9.0 V : Vcc = 12 V, Vo = 10.0 V : Vcc = 13 V
*12
Parameter
Parameter
Parameter
*9
TO252-3
TO252-5
TO220FP-3
TO220FP-5
TO220FP-5 (V5)
TO220CP-V5
Parameter
*10
*8
Symbol
T
Symbol
V
T
Symbol
T
P
Reg.L
Reg.I
Reg.L
jmax
Tcvo
Reg.I
∆Vd
Tcvo
CC
opr
stg
∆Vd
d
Isd
Vo
Isd
Vc
Io
Io
CTL
= 3 V; V
Symbol
V
Vc
CC *5
V
I
Vo (T)
1.225
0.98
C *6
o
Min.
Min.
o
1
1
-
-
-
-
-
-
-
-
-
-
CCDC *7
CTL
−40 to +105
−55 to +150
Limits
2/8
= 3 V, R1 = 30 k, R2 = 30 k
1.250
0.02
150
Typ.
1200
1300
2000
2000
2000
2000
0.3
Vo (T)
15
35
0.02
)
0
Typ.
-
18
0.3
15
35
0
-
*1
*2
*3
*4
*4
*4
*4
V
1.275
Max.
Min.
o
0.5
3.0
1.5
10
30
75
+1.0
-
-
-
Vo (T)
 1.02
Max.
0.5
10
35
75
-
-
%/°C
mW
Unit
Unit
mV
mV
A
°C
°C
°C
V
V
A
V
%/°C
Unit
mV
mV
A
V
V
A
VCTL = 0 V while in OFF mode
Io = 50 mA
Io = 500 mA, Vcc = 2.5V
Vcc = Vo + 1.0 V→16V, Io = 200 mA
Io = 0 mA →1A
Io = 5mA, Tj=0°C to 125°C
Io = 200mA
VCTL = 0 V while in off mode
Io = 200 mA,Vcc = 0.95  Vo
Vcc = Vo+1.0V→16V, Io = 200mA
Io = 0 mA →1 A
Io = 5 mA、Tj = 0°C to 125℃
Max.
*11
16.0
16.0
12
1
)
Conditions
Conditions
Technical Note
2010.02 - Rev.B
Unit
V
V
A
V

Related parts for BA60BC0WT