LVR008S Tyco Electronics, LVR008S Datasheet - Page 2

POLYSWITCH 240VAC .08A HOLD

LVR008S

Manufacturer Part Number
LVR008S
Description
POLYSWITCH 240VAC .08A HOLD
Manufacturer
Tyco Electronics
Series
PolySwitch®r
Datasheet

Specifications of LVR008S

R Min/max
7.400 ~ 12.00 Ohm
Voltage - Max
240V
Time To Trip
15s
Current - Hold (ih) (max)
80mA
Current - Trip (it)
190mA
Current - Max
1.2A
Package / Case
Radial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Tyco/Electronics
Raychem Circuit Protection
308 Constitution Drive
Menlo Park, CA 94025-1164
800-227-4856
FAX 800-227-4866
1. Users should independently evaluate the suitability of and test each product selected for their
2. This product should not be used in an application where maximum interrupt voltage or
3. A PTC device is not a fuse - it is a nonlinear thermistor that limits current. Because under a
4. The devices are intended for protection against occasional overcurrent or overtemperature
5. In most applications, power must be removed and the fault condition cleared in order to reset a
6. It is the responsibility of the user to determine the need for back up or fail safe protection to
7. Operation in circuits with a large inductance can generate a circuit voltage (Ldi/dt) above the
8. Devices are not recommended for reflow soldering.
9. Device performance can be impacted negatively if devices are handled in a manner
10. PTC devices are not recommended to be installed in applications where the device is
11. Contamination of the PTC material with certain silicone-based oils or some aggressive
own application.
maximum interrupt current can be exceeded in a fault condition. Operation beyond the
maximum ratings or improper use may result in device damage and possible electrical arcing
and flame.
fault condition all PTC devices go into a high resistance state but not open circuit, hazardous
voltage may be present at PTC locations
fault conditions and should not be used when repeated fault conditions or prolonged trip events
are anticipated.
PTC device. However, under certain unusual conditions, a PTC device may automatically
reset (see Raychem Circuit Protection Databook). Accordingly, PTC devices should not be
used in an application where an automatic reset could create a safety hazard, such as garbage
disposals and blenders.
prevent damage that may occur in the event of abnormal function or failure of the PTC device.
rated voltage of a PTC device.
inconsistent with recommended electronic, thermal, or mechanical procedures for electronic
components.
constrained such that its PTC properties are inhibited, for example in rigid potting materials or
in rigid housings which lack adequate clearance to accommodate device expansion.
solvents can adversely impact the performance of the devices.
Warning: Application Limitations for LVR Product Line
Overcurrent Protection Device
PolySwitch®
PTC Devices
.
PRODUCT: LVR008S
DOCUMENT: SCD 24903
PCN: 029390
REV LETTER: H
REV DATE: JUNE 18, 2003
PAGE NO.: 2 OF 2

Related parts for LVR008S