Specifications of 2410-31-G-MSP

Voltage - Clamping
350V
Technology
Mixed Technology
Number Of Circuits
1
Applications
Telecommunications
Package / Case
Radial - 5 Lead
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Power (watts)
-
Voltage - Working
-
Lead Free Status / RoHS Status
Not Compliant, Contains lead / RoHS non-compliant
Bourns
life in overvoltage protection of copper pair voice-band and high-speed data circuits. Bourns MSP
tube and solid state protection while integrating three advanced technologies: a proprietary high-effi ciency gas discharge tube,
precision matched metal oxide varistors and a patented Switch-Grade Fail-Short mechanism. The Switch-Grade Fail-Short
mechanism ensures superior thermal protection with fast acting, highly reliable response to thermal overload conditions. This
combined technology provides lower capacitance, higher reliability and longer life than competitive hybrid technologies.
Bourns
protocols and high speed Ethernet. Bourns
copper communications circuits. The 2410 series is the most economical, reliable and effective choice for overvoltage protection of
copper pair circuits.
DC Breakdown ............................................................................................................................................... 300-400 V
AC Breakdown @ 60 Hz ................................................................................................................................. 300-400 V
Impulse Breakdown
Insulation Resistance @ 100 Vdc ................................................................................................................... >1 GΩ
Insertion Loss @ 100 MHz .............................................................................................................................. <0.4 dB
Return Loss @ 100 MHz ................................................................................................................................. >14 dB
Capacitance Tip to Ring @ 1 MHz ................................................................................................................. 10 pF typical
Capacitance Tip or Ring to Ground @ 1 MHz ................................................................................................ 20 pF typical
Impulse Reset
Impulse Life Characteristics (Tip and Ring to Ground Simultaneously)
AC Life Characteristics (Tip and Ring to Ground Simultaneously)
High Current Capability and Thermal Operation (Tip and Ring to Ground,
Vented or Non-Vented Gas Tube) ................................................................................................................... >30 A rms, simultaneously
Storage and Operating Temperature .............................................................................................................. -55 to +85 °C
Telcordia analyzed for controlled (non-sealed) and uncontrolled, high-exposure (sealed) environments per GR 974 and SBC SR 5165.
Telcordia Technical Analysis Report DA-1547.
Notes:
1
2
3
4
5
Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications
Test Methods per UL 497, CSA C22.2, Telcordia GR 974, 1361 and SBC SR 5165.
Tested according to Category 5 requirements
Exceeds Telcordia (Bellcore) GR 1361
Surpasses Telcordia GR 974
RUS (REA) PE-80
Network applied
Characteristics
100 V/µs .................................................................................................................................................... 600 V
1000 V/µs .................................................................................................................................................. 650 V
52 V, 260 mA ............................................................................................................................................. <10 ms
135 V, 200 mA ........................................................................................................................................... <10 ms
150 V, 200 mA ........................................................................................................................................... <150 ms
10 to 100 A, 10/1000 µs ............................................................................................................................ >3000 operations
300 A, 10/1000 µs ..................................................................................................................................... >1000 operations
500 A, 10/1000 µs ..................................................................................................................................... >1000 operations
2,000 A, 10/250 µs .................................................................................................................................... >100 operations
5,000 A, 20/100 µs .................................................................................................................................... >10 operations
20,000 A, 8/20 µs ...................................................................................................................................... >10 operations
0.5 A rms continuous ................................................................................................................................ >30 seconds
1 A rms, 1 second, 600 ft. cable ............................................................................................................... >60 seconds
1 A rms, 1 second, 1 mile cable ................................................................................................................ >60 operations
10 A rms, 1 second ................................................................................................................................... >5 operations
65 A rms, 11 cycles ................................................................................................................................... >1 operation
120 A rms, 0.1 second .............................................................................................................................. 1 operation
®
®
5-Pin Multi-Stage Protector (MSP
2410 can be used universally for POTS and high speed data, e.g. ISDN, ADSL, ADSL2+, VDSL, VDSL2, other xDSL
5
®
) is the latest generation telecommunications protector for high performance and long
®
MSP
2410 Series - 5-Pin Multi-Stage Protector (MSP
Features
Patented Multi-stage protection (MSP
Balanced TRIGARD
Patented Switch-Grade Fail-Short Device
Quick response and high energy handling
Ideal for high-speed networks in high
exposure environments
C
U L
®
®
technology provides unparalleled overvoltage protection with low loss on paired
US LISTED
per UL 497 (File: 53117)
®
®
)
Meets test requirements of Telcordia
GR 974, GR1361, SBC SR 5165 and
RUS PE-80
Telcordia Analysis report DA-1547
Solid brass, gold-plated pins
Test point access option
Sealed option for harsh environments
®
combines the advantages of gas
1
1
®
3
)
2
4
2
2
2
4

Related parts for 2410-31-G-MSP

2410-31-G-MSP Summary of contents

Page 1

... Bourns ® 2410 can be used universally for POTS and high speed data, e.g. ISDN, ADSL, ADSL2+, VDSL, VDSL2, other xDSL protocols and high speed Ethernet. Bourns copper communications circuits. The 2410 series is the most economical, reliable and effective choice for overvoltage protection of copper pair circuits ...

Page 2

... Multi-Stage Protector BC = Balanced Capacitance* Special Options S = Sealed Case ST = Sealed Case and Test Points Test Points** *For use on DSL Systems that require balanced capacitance of ≤1 pF. **T and ST options are not available on 2410-7x short module. Product Dimensions 12.8 (0.50) 2.2 DIA. 2 PLCS. (.085) 19 ...

Related keywords