P0080SCMC Littelfuse / Teccor Sidactor(R) Product, P0080SCMC Datasheet - Page 161

no-image

P0080SCMC

Manufacturer Part Number
P0080SCMC
Description
SIDACTOR MC BI 6V 400A DO-214AA
Manufacturer
Littelfuse / Teccor Sidactor(R) Product
Series
SIDACtor® SC(MC)r
Datasheet

Specifications of P0080SCMC

Voltage - Breakover
25V
Voltage - Off State
6V
Voltage - On State
5V
Current - Peak Pulse (8 X 20µs)
400A
Current - Peak Pulse (10 X 1000µs)
100A
Current - Hold (ih)
50mA
Number Of Elements
1
Capacitance
75pF
Package / Case
DO-214AA, SMB
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P0080SCMC
Manufacturer:
Littelfuse
Quantity:
45 000
Part Number:
P0080SCMCL
Manufacturer:
Littelfu
Quantity:
150 000
Part Number:
P0080SCMCLRP
Manufacturer:
Littelfu
Quantity:
73 500
Part Number:
P0080SCMCLRP
Manufacturer:
LITTELFUSE/力特
Quantity:
20 000
Part Number:
P0080SCMCRP
Manufacturer:
Littelfu
Quantity:
30 000
Surge Waveforms for Various Standards
© 2002 Teccor Electronics
SIDACtor
®
Data Book and Design Guide
TIA-968 now replaces FCC Part 68, except for hearing aid compatibility (HAC), volume
control, and indoor cabling. This has become harmonized with Canadian requirements.
Various countries around the world have adopted this regulation.
GR 1089 is a standard generally supported by the US Regional Bell Operating Companies
(RBOC). It is updated by Telcordia Technology (formerly Bellcore). The RBOC typically
requires compliance with GR 1089 for any of their telecom purchases.
ITU is a specialized agency of the UN devoted to international harmonization. Most
European countries recognize the ITU standards.
CNET is the Centre National d’etudes de Telecommunications, a French organization.
VDE is the Verband Deutsher Elektrotechniker, a Federation of German electrical
engineers. VDE is very similar to the IEEE (Institute of Electrical and Electronics Engineers)
but is national in scope rather than global.
ANSI is the American National Standards Institute, which is a non-government organization.
The British equivalent to this is BSI.
IEC is the International Electrotechnical Commission, a result of Europe’s move toward a
single market structure and its drive to formalize and harmonize member countries’
requirements.
FTZ R12 is a German specification.
Table 4.19 and Table 4.20 show the recommended SIDACtor device surge rating for each
standard.
4 - 37
Surge Waveforms for Various Standards
http://www.teccor.com
+1 972-580-7777