S20K300E2 EPCOS Inc, S20K300E2 Datasheet - Page 12

VARISTOR 300V RMS 20MM RADIAL

S20K300E2

Manufacturer Part Number
S20K300E2
Description
VARISTOR 300V RMS 20MM RADIAL
Manufacturer
EPCOS Inc
Series
AdvanceDr
Datasheet

Specifications of S20K300E2

Varistor Voltage
470V
Current-surge
10kA
Number Of Circuits
1
Maximum Ac Volts
300VAC
Maximum Dc Volts
385VDC
Energy
250J
Package / Case
Disc 20mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
495-1449
B72220S2301K101

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S20K300E2
Manufacturer:
FUJISU
Quantity:
5 000
Reliability data
Test
Varistor voltage
Clamping voltage
Max. AC operating voltage
Surge current derating,
8/20 µs
Surge current derating,
2 ms
Electric strength
Please read Cautions and warnings and
Important notes at the end of this document.
Leaded varistors
AdvanceD series
Test methods/conditions
The voltage between two terminals with
the specified measuring current applied
is called V
The maximum voltage between two
terminals with the specified standard
impulse current (8/20 µs) applied.
CECC 42 000, test 4.20
1000 h at UCT
After having continuously applied
the maximum allowable voltage at UCT
±2 °C for 1000 h, the specimen shall be
stored at room temperature and normal
humidity for 1 to 2 h.
Thereafter, the change of V
measured.
CECC 42 000, test C 2.1
100 surge currents (8/20 µs), unipolar,
interval 30 s, amplitude corresponding
to derating curve for 100 impulses at
20 µs
CECC 42 000, test C 2.1
100 surge currents (2 ms), unipolar,
interval 120 s, amplitude corresponding
to derating curve for 100 impulses at
2 ms
CECC 42 000, test 4.7
Metal balls method, 2500 V
The varistor is placed in a container
holding 1.6 ±0.2 mm diameter metal
balls such that only the terminations of
the varistor are protruding.
The specified voltage shall be applied
between both terminals of the speci-
men connected together and the elec-
trode inserted between the metal balls.
v
(1 mA
DC
12
@ 0.2 … 2 s).
11/07
RMS
v
shall be
, 60 s
Requirement
To meet the specified value.
To meet the specified value.
|
|
(measured in direction
of surge current)
No visible damage
|
(measured in direction
of surge current)
No visible damage
No breakdown
∆V/V (1 mA)
∆V/V (1 mA)
∆V/V (1 mA)
|
|
|
≤10%
≤10%
≤10%