E3X-NA6 Omron, E3X-NA6 Datasheet - Page 14

no-image

E3X-NA6

Manufacturer Part Number
E3X-NA6
Description
CONN READY NPN GEN PURPOSE FO
Manufacturer
Omron
Series
E3X-NAr
Datasheets

Specifications of E3X-NA6

Amplifier Type
Wire Saving
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
35mA
Mounting Type
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3XNA6
E3XNA6Q
14
E3X-SD/-NA
Amplifier Units with Connectors
● Mounting
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit
2. Join Amplifier Units together as required after all the Master
3. Attach the stickers (provided as accessories) to the sides of
Note: Attach the stickers to the sides with grooves.
Removing Connectors
1. Slide the slave Amplifier Unit for which the Connector is to
2. After the Amplifier Unit has been separated, press down on
until it clicks into place.
and Slave Connectors have been inserted.
Master and Slave Connectors that are not connected to
other Connectors.
be removed away from the rest of the group.
the lever on the Connector and remove it. (Do not attempt
to remove Connectors without separating them from other
Amplifier Units first.)
Sticker
Insert
Press down
Sticker
Remove
Lever
Mounting End Plate (PFP-M)
Depending on how it is mounted, an Amplifier Unit may move
during operation. In this case, use an End Plate.
Before mounting an End Plate, remove the clip from the
master Amplifier Unit using a nipper or similar tool.
The clip can also be removed using the following mechanism,
which is incorporated in the construction of the section
underneath the clip.
1. Insert the clip to be removed into the slit underneath the clip
2. Remove the clip by rotating the Amplifier Unit.
Pull Strengths for Connectors (Including Cables)
E3X-CN11: 30 N max.
E3X-CN12: 12 N max.
on another Amplifier Unit.
Rotate
Clip