E3C-LDA11AT Omron, E3C-LDA11AT Datasheet - Page 19

AMP ATC LASER TYPE NPN-OUTPUT

E3C-LDA11AT

Manufacturer Part Number
E3C-LDA11AT
Description
AMP ATC LASER TYPE NPN-OUTPUT
Manufacturer
Omron
Series
E3C-LDAr
Datasheet

Specifications of E3C-LDA11AT

Amplifier Type
ATC Output
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
45mA
Mounting Type
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3CLDA11AT
Ratings and Specifications
Amplifier Units
*1. Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual interference prevention
*2. PNP output is as follows: Operate: 53 s, reset: 55 s.
*3. Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled.
Item
Light source (wavelength)
Power supply voltage
Power consumption
Control output
Protection circuits
Re-
sponse
time
Sensitivity setting
Func-
tions
Display
Digital display
Display orientation
Ambient illumination
(Receiver side)
Ambient temperature range
Ambient humidity range
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Materials
Accessories
and the Mobile Console will not function.
Super-high-
speed mode
High-speed
mode
Standard mode
High-resolution
mode
Power tuning
Timer function
Automatic power
control (APC)
Zero-reset
Initial reset
Mutual interfer-
ence prevention
Case
Cover
Model
Type
Red LED (635 nm)
12 to 24 VDC 10%, ripple (p-p) 10% max.
960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC)
Load power supply voltage: 26.4 VDC; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 1 V max.
Reverse polarity for power supply connection, output short-circuit
Operate or reset: 1 ms
Teaching or manual method
High-speed control method for emission current
Settings can be returned to defaults as required.
Possible for up to 10 Units *3
Operation indicator
(orange)
incident level +
threshold
Incandescent lamp: 10,000 lux max.
Sunlight:
Operating: Groups of 1 to 2 Amplifiers: 25 C to 55 C
Storage:
Operating and storage: 35% to 85% (with no condensation)
20 M
1,000 VAC at 50/60 Hz for 1 minute
Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Destruction: 500 m/s
IEC 60529 IP50 (with Protective Cover attached)
Pre-wired or amplifier unit connector
Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g
Polybutylene terephthalate (PBT)
Polycarbonate (PC)
Instruction manual
Single-function
E3X-DA@SE-S
models
min. (at 500 VDC)
---
---
---
---
---
---
---
Groups of 3 to 10 Amplifiers: 25 C to 50 C
Groups of 11 to 16 Amplifiers: 25 C to 45 C
30 C to 70 C (with no icing or condensation)
20,000 lux max.
2
, for 3 times each in X, Y and Z directions
Operate: 48 s, reset: 50 s *1, *2
Operate/reset: 250 s
Operate or reset: 4 ms
Light emission power and reception gain, digital control method
Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments,
200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)
Negative values can be displayed. (Threshold value is shifted.)
Operation indicator (orange), Power Tuning indicator (orange)
Select from incident level + threshold or other 6 patterns
Switching between normal/reversed display is possible.
E3X-DA@-S
Standard
models
Green LED (525 nm) Blue LED (470 nm)
E3X-DAG@-S
Mark-detecting models (multiple color light sources)
Green LED
E3X-DAB@-S
Blue LED
Refer to pages
E3X-DA-S/MDA
Infrared LED
(870nm)
17 to 20 for dimensions.
E3X-DAH@-S
Infrared LED
5

Related parts for E3C-LDA11AT