Specifications of C1608X7R1H334K

Capacitance
0.33µF
Tolerance
±10%
Package / Case
0603 (1608 Metric)
Voltage - Rated
50V
Temperature Coefficient
X7R
Mounting Type
Surface Mount, MLCC
Operating Temperature
-55°C ~ 125°C
Features
Low ESR
Applications
General Purpose
Size / Dimension
0.063" L x 0.031" W (1.60mm x 0.80mm)
Thickness
0.80mm
Voltage Rating
50 Volts
Operating Temperature Range
- 55 C to + 125 C
Temperature Coefficient / Code
X7R
Product
General Type MLCCs
Dimensions
0.8 mm W x 1.6 mm L x 0.8 mm H
Termination Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Ratings
-
Lead Spacing
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
445-5950-2
• All specifications are subject to change without notice. Please read the precautions before using the product.
No.
16
General
Specifications
Item
Moisture Resistance
External
appearance
Capacitance
Q
(Class 1)
D.F.
(Class 2)
Insulation
Resistance
Performance
No mechanical damage.
* Inside ( ) is applied to Y5V 6.3V
product.
Characteristics
X5R: 200% of initial spec. max.
X7R: 200% of initial spec. max
Y5V: 150% of initial spec. max
500MΩor 25MΩ•μF min., whichever
smaller.
(As for the capacitors of rated voltage
16, 10 and 6.3V DC, 500 MΩ or
5MΩ•μF min.,)
Characteristics
Class 1
Class 2
Rated
Capacitance
C ≥ 30pF
C < 30pF
C0G
X5R
X7R
Y5V
C : Rated capacitance (pF)
Change from the
value before test
±7.5% or ±0.75pF,
whichever larger.
± 25 %
± 25 %
± 30 % *(± 40 %)
Q
200 min.
100+10/3×C min.
C Series — General Application
Test or Inspection Method
Reflow solder the capacitor on P.C. board (shown in
Appendix 1a or Appendix 1b) before testing.
Apply the rated voltage at temperature 40±2ºC and 90
to 95%RH for 500 +24,0h.
Charge/discharge current shall not exceed 50mA.
Leave the capacitor in ambient conditions for 6 to 24h
(Class 1) or 24±2h (Class 2) before measurement.
Voltage conditioning (only for Class 2):
Voltage treat the capacitor under testing temperature
and voltage for 1 hour.
Leave the capacitor in ambient conditions for 24±2h
before measurement.
Use this measurement for initial value.
US Catalog // C Series — General Application // Version A11

Related parts for C1608X7R1H334K