POE60U-560G PHIHONG USA, POE60U-560G Datasheet - Page 3

no-image

POE60U-560G

Manufacturer Part Number
POE60U-560G
Description
ADAPTER 60W HI POWER 1PORT
Manufacturer
PHIHONG USA
Type
Single Port, Midspan Injectorr
Datasheet

Specifications of POE60U-560G

Power (watts) - Per Port
60W
Number Of Ports
1
Voltage - Input
90 ~ 264VAC
Voltage - Output
56VDC
Current - Output
550mA
Mounting Type
Desktop
Size / Dimension
6.53" L x 3.15" W x 1.73" H (166mm x 80mm x 44mm)
Input Connector
IEC320-C14
Efficiency
75%
Operating Temperature
0°C ~ 40°C
Features
Compliant with the IEEE802.3af Standard
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
993-1091
Power-up Sequence:
Detection Sequence:
Fault Sequence:
Dimension Diagram Unit:mm
Upon power-up, all 3 LEDs will light for 2 seconds, as part of the self-test for the internal
microprocessor software. After the 2 second period, the "ON" LED will illuminate green. The DC
output voltage is available for powering a compliant load (to the 802.3af PoE standards).
Once a compliant load is attached to the output RJ45 connector, the green "CONNECT" LED will
illuminate.
Should the load be non-compliant then the LEDs will blink a code specific to the cause for non-
detection.
Detection Failure Codes:
1. Incorrect resistive signature – The green “CONNECT” and red “FAULT” LEDs will blink 3 times.
2. Incorrect capacitive signature – The green “ON” LED will blink 3 times.
3. Incorrect Voffset – The green “CONNECT” and green “ON” LEDs will blink 3 times.
4. Unstable current measurement – The green “ON” LED will blink 3 times
5. Low voltage sensed during detection (overload) – The red “FAULT” LED will blink 3 times
After the LEDs blink 3 times the Power Injector will continue to try to detect a valid load. Until the
correct load is applied, the LEDs will continue to blink. If there is an open circuit connected to the
output RJ45 then the LEDs will not blink but the Power Injector will continue to try to detect a valid
load.
Should there be a fault such as an overload or short circuit then the red "FAULT" LED will illuminate.
The red “FAULT” LED will illuminate for 2 seconds and then go off as the power supply tries to re-
detect a valid load. If there is a problem detecting the load, the LED will indicate the possible fault as
per the codes in the section above.
Description of LED Functions for Gigabit Power Injector
WWW.PHIHONG.COM