2866598 Phoenix Contact, 2866598 Datasheet

UPS 4A 12VDC

2866598

Manufacturer Part Number
2866598
Description
UPS 4A 12VDC
Manufacturer
Phoenix Contact
Series
Minir
Datasheets

Specifications of 2866598

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
48W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
DIN Rail
1st Output
12 VDC @ 4A
Size / Dimension
4.53" L x 2.66" W x 3.90" H (115mm x 67.5mm x 99mm)
Operating Temperature
-25°C ~ 70°C
Power (watts) - Rated
48W
Efficiency
82%
Approvals
cUL, EN, UL, VDE
Output Voltage Rating
12 V
Number Of Outlets
1
Tower / Rackmount
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
MINI-DC-UPS/12DC/4
Uninterruptible power supply with integrated power
supply unit
INTERFACE
Data sheet
104211_en_00
1
The MINI-DC-UPS provide an uninterruptible DC voltage
both in case of AC power supply network and in the event of
mains interferences. The wide-range input allows input
voltages from 85 V AC to 264 V AC; 4 A is provided at the
output with a regulated and adjustable output voltage from 10
V DC to 16 V DC. The rechargeable battery module supplies
an output voltage from 13.8 V DC to 9.6 V DC in buffer mode.
A 1.6 Ah or a 2.6 Ah rechargeable battery module is optionally
used depending on the required buffer time. The buffer time
varies depending on the load current.
Description
DANGER OF EXPLOSION!
Only remove equipment when it is disconnected and not in the potentially explosive area.
The device contains dangerous live elements and high levels of stored energy.
Never carry out work when the power is turned on.
Make sure you always use the latest documentation.
It can be downloaded from the product at www.phoenixcontact.net/catalog.
© PHOENIX CONTACT - 01/2010
Features
Easy assembly on the DIN rail or panel
Quick startup with LED function monitoring
Buffer time of 0.5 to 30 minutes or permanently settable
Can be used worldwide in all industrial sectors due to a
wide-range input and an international approval package
Battery management for optimized, temperature-
compensated charging with simultaneous increase of
battery life
High operating safety due to long mains buffering under
full load and high MTBF (> 500,000 h)

Related parts for 2866598

2866598 Summary of contents

Page 1

... The device contains dangerous live elements and high levels of stored energy. Never carry out work when the power is turned on. Make sure you always use the latest documentation. It can be downloaded from the product at www.phoenixcontact.net/catalog. © PHOENIX CONTACT - 01/2010 Features – Easy assembly on the DIN rail or panel – ...

Page 2

... Assembly ...................................................................................................................................................................9 Removing...................................................................................................................................................................9 11 Connection, network forms 100...240 V AC networks ............................................................... 12 Input .......................................................................................................................................... 13 Output ....................................................................................................................................... Signaling outputs .....................................................................................................................................................11 14 Signaling ................................................................................................................................... 15 Rechargeable battery module ................................................................................................... 16 Remote shutdown ("Remote") ................................................................................................... Remote shutdown inactive .......................................................................................................................................12 Remote shutdown active..........................................................................................................................................12 17 Function .................................................................................................................................... Setting the output voltage ........................................................................................................................................13 Buffer time setting ....................................................................................................................................................13 104211_en_00 MINI-DC-UPS/12DC PHOENIX CONTACT ...

Page 3

... Ascent time Residual ripple Peak switching voltages Connection in parallel Surge protection against internal surge voltages Resistance to reverse feed 104211_en_00 Type Order No. MINI-DC-UPS/12DC/4 2866598 Type Order No. MINI-BAT/12DC/1.6AH 2866572 MINI-BAT/12DC/2.6AH 2866569 100 V AC ... 240 ... 264 V AC 100 V DC ... 350 V DC (UL508: 100...250 V DC) (Depending on the storage medium, e ...

Page 4

... IEC 61709 (SN 29500) Polyamide PA, color: green 67 115 mm 0.45 kg -25 °C ... 70 °C (> 60 °C derating) -40 °C ... 80 ° (at 25 °C, no condensation) < 15 Hz, amplitude ±2 acc. with IEC 60068-2 ... 150 Hz, 2.3g, 90 min. 30g in all directions in acc. with IEC 60068-2-27 2 3K3 (in acc. with EN 60721) MINI-DC-UPS/12DC/4 4 PHOENIX CONTACT ...

Page 5

... Criterion B EN 61000-4-5 Input 4 kV (level 4 - asymmetrical: conductor to ground (level 4 - symmetrical: conductor to conductor) Output 2 kV (Level 3 - asymmetrical (Level 3 - symmetrical) Signal 2 kV (Level 3 - asymmetrical (Level 3 - symmetrical) Comments Criterion B EN 61000-4-6 Input/Output/Signal Level 3 Frequency range 10 kHz ... 80 MHz Voltage 10 V Comments Criterion A MINI-DC-UPS/12DC/4 5 PHOENIX CONTACT ...

Page 6

... Emitted interference in acc. with EN 61000-6-3 Radio interference voltage in acc. with EN 55011 Emitted radio interference in acc. with EN 55011 104211_en_00 EN 61000-4-11 Input (mains buffering > 20 ms) Comments Criterion B EN 55011 (EN 55022) Class B, area of application: Industry and residential EN 55011 (EN 55022) Class B, area of application: Industry and residential MINI-DC-UPS/12DC/4 6 PHOENIX CONTACT ...

Page 7

... V DC ... (AC input voltage available, AC input voltage not available: Output voltage depending on the battery voltage: 13 ... 9 Pluggable COMBICON screw connections MINI-DC-UPS/12DC/4 2 [mm ] AWG [Nm] solid stranded Torque 0.2 - 2.5 0 0.5 - 0.6 0.2 - 2.5 0 0.5 - 0.6 0.2 - 2.5 0 0.5 - 0.6 PHOENIX CONTACT 7 ...

Page 8

... In order for the device to function in the manner intended not necessary to observe any minimum spacing to other devices. The power supply unit can be snapped onto all DIN rails in acc. with EN 60715. They must be mounted horizontally (connecting terminal blocks top and bottom). PHOENIX CONTACT 8 ...

Page 9

... Mounting on DIN rails 104211_en_00 110 115 Assembly To mount on a DIN rail, snap the device straight onto the DIN rail. Removing To remove from the DIN rail, press the base latch outward and pull the device off of the DIN rail. MINI-DC-UPS/12DC/4 9 PHOENIX CONTACT ...

Page 10

... The primary side line protection, for example, is suitable. For device protection, there is an internal fuse. Additional device protection is not necessary. MINI-DC-UPS/12DC CAUTION If an internal fuse is triggered, there is a device malfunction. In this case, the device must be inspected in the factory. PHOENIX CONTACT ...

Page 11

... The cables on the secondary side must have sufficiently large cross sections in order to keep the voltage drops on the lines as low as possible. Alarm LED off; output LED off; output LED off; output LED on; output LED on; output LED off; output PHOENIX CONTACT 11 ...

Page 12

... The rechargeable battery module is charged when the supply voltage is reconnected, but the device remains switched off until the remote shutdown is activated. – The connected consumers are fed as long as the supply voltage is available. MINI-DC-UPS/12DC/4 12 PHOENIX CONTACT ...

Page 13

... PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00 104211_en_00 PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300 Setting the output voltage In the normal mode, the output voltage of the device conforms to the setting on the potentiometer ( ...

Related keywords