ZAXM-201-KIT-1 CEL, ZAXM-201-KIT-1 Datasheet

KIT EVAL APEX MODULE

ZAXM-201-KIT-1

Manufacturer Part Number
ZAXM-201-KIT-1
Description
KIT EVAL APEX MODULE
Manufacturer
CEL
Type
802.15.4/Zigbeer
Datasheet

Specifications of ZAXM-201-KIT-1

Frequency
2.4GHz
Wireless Frequency
2.4 GHz to 2.5 GHz
Interface Type
SPI, I2C, UART
Security
128 bit AES
For Use With/related Products
ZAXM-201
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
DESCRIPTION
Apex modules provide a cost-effective RF transceiver solution for 2.4GHz
ZigBee and IEEE 802.15.4 data links and wireless networks.
The ZAXM-201-1 Apex module is based on the Ember™ EM250 plat-
form. It combines Ember’s transceiver IC and 16-bit microprocessor with
an onboard 100mW Power Amplifier. It’s designed to support point to
point, point to multi-point, and EmberZNet applications.
The APEX module provides over 4000 feet of range and is designed to
deliver constant RF output power across the 2.1 to 3.6V voltage input,
ensuring consistent performance over the entire life of the battery.
ORDERING INFORMATION
FEATURES
• 1 - 100mW output power, software controlled
• Designed for EmberZNet networks
• Miniature footprint: 1.00” x 1.275”
• Integrated PCB trace antenna
• Optional MMCX connector for external antenna
• 16 RF channels (Channel 16 operates at reduced power levels)
• Over 4000 feet of range
• Integrated hardware support for Ember InSight Development
• Non-intrusive debug interface (SIF)
• AES 128 bit encryption
• Low power consumption
• Constant RF output power over 2.1– 3.6 V voltage range
• FCC, IC, and CE certified
• RoHS compliant
Environment
ZAXM-200 Series
APEX MODULE
The information in this document is subject to change without notice, please confirm data is current.
Document No: 0002-00-07-00-000 (Issue C)
Date Published: April 29, 2010
Part Number
ZAXM-201-1
ZAXM-201-1C
ZAXM-201-KIT-1
Order Number
Integrated Transceiver Modules for ZigBee / IEEE 802.15.4
100 mW Output power, PCB Trace Antenna
100 mW Output power, with MMCX Connector for use with off board antenna
Engineering Evaluation Kit
DATA SHEET
APEX SERIES TRANSCEIVER MODULES
Evaluation Kit available: ZAXM-201-KIT-1
APPLICATIONS
• Security
• HVAC control
• Lighting control
• Thermostats
• In meter applications
• Thermostats
• In-home display units
Automated Meter
Reading
Home &
Building Automation
APEX MODULE
ZAXM-201-1
Supplying Form
• Ember™ EM250 platform
• 128kB Flash memory
• 5kB SRAM
• 16-bit XAP2b microprocessor
• 16 general purpose I/O ports
• DMA – SPI, I
• Integrated ADC with 12-bit resolution
ZAXM- 201-1
• Food processing controls
• Traffic Management
• Sensor Networks
• Asset Management
• Barcode reader
• Patient Monitoring
• Glucose monitor
Industrial Controls
2
C and UART interfaces

Related parts for ZAXM-201-KIT-1

ZAXM-201-KIT-1 Summary of contents

Page 1

... APEX MODULE ZAXM-201-KIT-1 The information in this document is subject to change without notice, please confirm data is current. Document No: 0002-00-07-00-000 (Issue C) Date Published: April 29, 2010 DATA SHEET APEX SERIES TRANSCEIVER MODULES Evaluation Kit available: ZAXM-201-KIT-1 APEX MODULE ZAXM-201-1 APPLICATIONS Automated Meter Reading • In meter applications • ...

Page 2

... GPIO headers. The Evaluation Kit also contains four AA batteries and two USB cables. For more detail information regarding Apex Evaluation Kit, refer to the Apex Module Evaluation Kit User Guide document. www.cel.com/pdf/misc/apexseries_ug.pdf) Order Number Description ZAXM-201-KIT-1 Engineering Evaluation Kit 24 MHz XTAL SOC RF Front End (NEC PA and ...

Page 3

... Recommended (Operating Condition).................................................................................................................................................. DC Characteristics.................................................................................................................................................................................. RF Characteristics.................................................................................................................................................................................. Pin Signal & Interfaces Pin Signals I/O Configuration................................................................................................................................................................ Apex I/O Pin Assignment....................................................................................................................................................................... Apex Module Dimensions...................................................................................................................................................................... PCB Copper Pattern Layout................................................................................................................................................................... PCB Stencil Pattern................................................................................................................................................................................ PCB Keep-Out Areas.............................................................................................................................................................................. Processing Agency Certifications Shipment, Storage & Handling References & Revision History ZAXM-200 Series ...

Page 4

... Do not place the antenna in a metallic or metallized plastic enclosure. • Keep plastic enclosures more from the antenna in any direction. C (master-only), or UART functionality. The 2 C (master-only) operation. The integrated ADC can 2 C Master mode Master mode) 2 TOP VIEW TOP VIEW ZAXM-200 Series TOP VIEW ...

Page 5

... Frequency = 2440 MHz 90 5 120 -10 -15 150 30 -20 -25 -30 180 0 210 330 240 300 270 Vertical Polarization Gain (dBi) min: -24.7 max: -9.6 avg: -14.8 Horizontal Polarization Gain (dBi) min: -8.1 max: +0.4 avg: -3.4 ZAXM-200 Series ...

Page 6

... Issuing commands through the SIF interface. In DEEP SLEEP the current consumption of the module will drop to 5.0μA (5.5μA with optional 32.768kHz oscillator enabled). For more detail information on modes of operation refer to Ember EM250 datasheet available at Ember’s website (www.ember.com) ZAXM-200 Series ...

Page 7

... XAP2b Code Development (APEX only) HOST PROTOCOL INTERFACE COMMANDS For information on Host Protocol Interface Commands and for other software-related documents refer to Ember’s website: http://www.ember.com/products_documentation.html SPECIFICATIONS — GPIO7 (APEX) Min Typ 0. ZAXM-200 Series Max Unit V 0.4 V 0.1 μA 10 µA 250 µ ...

Page 8

... Standby Mode: 10mW 100mW Value Unit 3.6 Vdc V + 0.3, DD Vdc Max 3.6 +10 dBm -45 to 125 °C Min Typ Max 2.1 3.6 2405 2480 - 20 3.3V unless otherwise noted) DD Min Typ 170 37 ZAXM-200 Series Unit V MHz ° Max Unit 0 0. kΩ μA 5 µA ...

Page 9

... Figure 1 shows the layout of the 28 edge castellations. PIN 19 PIN 10 PIN 28 PIN 1 Figure 1 (Top View) = 3.3V unless otherwise noted) DD Min Typ 2400 250 12 128 -92 -96 -93 - ZAXM-200 Series Max Unit 2483.5 MHz kbps MHz kB kB dBm dBm dBm dBm ...

Page 10

... GROUND GND Ground 28 GROUND GND Ground Unused I/O pins should be left unconnected and the pin state set via the Host Protocol Digital Input DO = Digital Output AI = Analog Input AO = Analog Output PI = Power Input GND = Ground ZAXM-200 Series C SDA SCL, or Capture 2 C Data Clock, 2 ...

Page 11

... DIMENSIONS: ZAXM-201-1 Apex 0.195 RF Shield 0.062 DIMENSIONS: ZAXM-201-1C Apex with Optional MMCX Connector Dimensions in inches. Tolerances = +/-0.005” unless otherwise noted. 0.195 RF Shield J2 0.062 0.205 Overall Height w/MMCX Connector Dimensions in inches. Tolerances = +/-0.005” unless otherwise noted. PIN 19: SIF_CLK MISO MOSI ...

Page 12

... PCB PASTE STENCIL PATTERN: Apex Dimensions in inches. Tolerances = +/-0.005” unless otherwise noted. 0.065 0.100 Pitch Typ 28 0.900 0.125 Typ 28 Pads 0.040 0.070 Typ 28 Pads PIN 1 Recommended Host PCB Board Edge 0.100 Typ 28 Pads 0.065 0.070 Typ 28 Pads PIN 1 ZAXM-200 Series ...

Page 13

... CEL can provide assistance with your PCB layout. Component Keep Out Area: No components within 0.100 inches of module Edge of Host PCB Recommended overhang for PCB Antenna = 0.230 0.050 If module does not overhang edge of host PCB, no components, copper or traces are allowed in this area ZAXM-200 Series ...

Page 14

... After soldering the Module to the host board, consider optical inspection to check the following: • Proper alignment and centering of the module over the pads. • Proper solder joints on all pads. • Excessive solder or contacts to neighboring pads, or vias. ZAXM-200 Series 3º/sec max 150ºC 200ºC 60-120 sec 217ºC 60-150 sec 260 + 0º ...

Page 15

... Never attempt a rework on the module itself, e.g. replacing individual components. Such actions will terminate warranty coverage. Additional Grounding Attempts to improve module or system grounding by soldering braids, wires, or cables onto the module RF shield cover is done at the customers own risk. The numerous ground pins at the module perimeter should be sufficient for optimum immunity to external RF interference. ZAXM-200 Series ...

Page 16

... The APEX module is CE certified. The CE marking must be affixed legibly and indelibly to a visible location on the user’s product. FCC Approved Antennas • Integrated PCB trace antenna • Nearson S131CL-5-RMM-2450S – A 2.4GHz Dipole antenna with a 5 inch cable and a right angle MMCX connector. ZAXM-200 Series ...

Page 17

... According to JEDEC ISP, the Apex Module is moisture sensitive devices. Appropriate handling instructions and precautions are summarized in Section 2.1. Read carefully to prevent permanent damage due to moisture intake. Moisture Sensitivity Level (MSL) MSL 3, per J-STD-033 ZAXM-200 Series ...

Page 18

... To minimize risks of damage to property or injury (including death) to persons arising from defects in CEL products, customers must incorporate sufficient safety measures in their design, such as redundancy, fire-containment and anti-failure features. ZAXM-200 Series Page N/A N/A ...

Related keywords