UGWKEC8VEA1-EK Unigen Corp, UGWKEC8VEA1-EK Datasheet - Page 18

EVALUATION KIT ECHO 800

UGWKEC8VEA1-EK

Manufacturer Part Number
UGWKEC8VEA1-EK
Description
EVALUATION KIT ECHO 800
Manufacturer
Unigen Corp
Series
Echor
Type
Transceiver, UHFr
Datasheets

Specifications of UGWKEC8VEA1-EK

For Use With/related Products
Echo 800
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
784-1033
Solutions for a Real Time World
By default the configuration set#1 is used and register RTParam_switch_ext is set to ‘0’.
Note that a new value of the ConfigSwitch register or at the SWITCH pin should be modified when
the EN signal is low. The actual switch to the newly selected set of SWParam register will be
applied to the transceiver on the next rising edge of the EN signal.
Re-Tek - 1533
94539
support@unigen.com
http://www.unigen.com
ConfigSwitch
Register
X
X
0
1
SWITCH is an output: ‘1’ in
SWITCH is an output: ‘1’ in
transmitter mode ‘0’ in the
transmitter mode ‘0’ in the
SWITCH pin
other modes
other modes
0
1
PAN 433/868/902 MHz - UGW3S
Copyright Unigen Corporation, 2008
RTParam_switch_ext
ConfigSwitch
configuration
parameter
- 18 -
0
0
1
1
SWParam configuration set selected
Set #1: SWParam_mode_1
SWParam_Power_1 SWParam_Rmode_1
SWParam_t_delsig_in_1 SWParam_freq_1
Set #2: SWParam_mode_2
SWParam_Power_2 SWParam_Rmode_2
SWParam_t_delsig_in_2 SWParam_freq_2
Set #1: SWParam_mode_1
SWParam_Power_1 SWParam_Rmode_1
SWParam_t_delsig_in_1 SWParam_freq_1
Set #2: SWParam_mode_2
SWParam_Power_2 SWParam_Rmode_2
SWParam_t_delsig_in_2 SWParam_freq_2