CL4790-1000-232 Laird Technologies, CL4790-1000-232 Datasheet - Page 27

TXRX 900MHZ RS232 1W W/ANT DB9

CL4790-1000-232

Manufacturer Part Number
CL4790-1000-232
Description
TXRX 900MHZ RS232 1W W/ANT DB9
Manufacturer
Laird Technologies
Series
AeroCommr
Datasheets

Specifications of CL4790-1000-232

Function
Transceiver
Modulation Or Protocol
FHSS, FSK
Frequency
902MHz ~ 928MHz
Applications
General Purpose
Interface
RS-232
Sensitivity
-99dBm
Power - Output
1000mW
Data Rate - Maximum
115.2kbps
Voltage - Supply
7 V ~ 18 V
Package / Case
Module
Wireless Frequency
900 MHz
Interface Type
RS-232, RS-485
Board Size
121 mm x 70 mm x 30 mm
Modulation
FHSS, FSK
Security
1 byte System ID, DES
Operating Voltage
100 V to 120 V
Output Power
1000 mW
Antenna
Dipole
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CL4790 User’s Manual
4.2.2.6 Programming the CN4790 units
6/24/2005
1. Connect a CN4790 unit to the serial communications port on the PC.
2. Connect the power supply to the CN4790 unit. Make sure the Pwr LED is on.
3. Start the CN4790 Configuration Utility.
4. Select the COM Port that is connected to the CN4790 unit on the PC Settings section.
5. Select the Interface Baud Rate of the CN4790 unit. All CN4790 units are shipped with a
6. Select Read Radio to display the current settings of the CN4790 unit.
7. Change desired settings.
8. After all changes have been made, select Write Radio to save the changes.
9. Cycle Power to the unit after all changes has been saved. This will set the CN4790 unit
default rate of 57600 (unless units have been pre-configured to match specific serial
settings). If the Interface Baud Rate of the CN4790 unit is changed as described in
Section 4.2 Changing CN4790 Settings, then PC Setting Baud Rate must be set to the
same Baud Rate to allow proper programming of the units.
to its normal mode of operation.
27

Related parts for CL4790-1000-232