CL4424-100-232 Laird Technologies, CL4424-100-232 Datasheet - Page 20

TXRX 2.4GHZ RS232 100MW W/ANT

CL4424-100-232

Manufacturer Part Number
CL4424-100-232
Description
TXRX 2.4GHZ RS232 100MW W/ANT
Manufacturer
Laird Technologies
Series
AeroCommr
Datasheets

Specifications of CL4424-100-232

Function
Transceiver
Modulation Or Protocol
FHSS, FSK
Frequency
2.4GHz
Applications
General Purpose
Interface
RS-232
Sensitivity
-99dBm
Power - Output
100mW
Data Rate - Maximum
288kbps
Features
RS 232 Interface
Voltage - Supply
7 V ~ 18 V
Package / Case
Module
Wireless Frequency
2.4 GHz
Interface Type
RS-232, RS-485
Board Size
121 mm x 70 mm x 30 mm
Modulation
FHSS, FSK
Security
1 byte System ID
Operating Voltage
100 V to 120 V
Output Power
100 mW
Antenna
Dipole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
CL4424 User’s Manual
5. Troubleshooting
Problem
Read Radio displays error message: “Radio not
responding.”
Write Radio displays error message: “Radio not
responding.”
Garbled Data received.
Client’s Link LED does not come on.
Link LED is on, but data does not get transmitted or
received.
If these troubleshooting tips do not resolve the problem, please call our toll free number at:
(800) 492-2320, extension 207. Technical support hours are Monday through Friday, 8:00 am to
5:00 pm Central Standard Time.
6/21/2005
Solution
1.
2.
3.
4.
1.
2.
1.
1.
2.
3.
4.
5.
1.
2.
3.
Verify the PC Settings. See Section 4.2.3 PC
Settings.
Make sure the CL4424 unit uses the right serial
cable. Refer to Section 2.1 RS-232.
If any other program is running and is using the
same COM port as the CL4424, close that
program and try to read the radio again.
Reset the radio by cycling power after each
unsuccessful Read.
Verify that the baud rate of the CL4424 matches
that of the CL4424 host device.
Make sure the CL4424 unit(s) is connected to
the correct COM Port.
Check the COM port settings for correct Baud
Rate. Units can have transmission errors with
Flow Control set to Xon/Xoff.
Try increasing the Maximum Transmit Attempts
(for Clients) and/or Broadcast Attempts (for
Servers) values in small increments until
communication is established.
Connect a Null Modem adapter between the
Client and its host device.
Check the Destination Address setting.
Make sure the unit is connected to power.
Cycle power to the radio.
Verify the Channel Number and System ID
settings.
Cycle power to the radio.
Read the radio and make desired changes and
then Write the radio.
20

Related parts for CL4424-100-232