CME8000-TLSH C-Max, CME8000-TLSH Datasheet - Page 20

no-image

CME8000-TLSH

Manufacturer Part Number
CME8000-TLSH
Description
IC RECEIVER RC BICMOS 28-SSOP
Manufacturer
C-Max
Datasheet

Specifications of CME8000-TLSH

Frequency
40kHz ~ 120kHz
Sensitivity
-115dBm
Modulation Or Protocol
UTC - Universal Time Code
Applications
Radio Controlled Time
Current - Receiving
2mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Voltage - Supply
1.2 V ~ 5 V
Operating Temperature
-40°C ~ 85°C
Package / Case
28-SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Memory Size
-
Data Rate - Maximum
-
Other names
561-1007-5
CME8000-TL
CME8000 digital out:
0.5s
0.5s
C-MAX
19 Information on the Japanese Transmitter
Station:
Frequency:
Transmitting power:
Station:
Frequency:
Transmitting power:
Modulation
The carrier amplitude is 100% at the beginning of
each second and is switched to 10% after 500 ms
(binary one) or after 800 ms (binary zero) or after
200 ms for Position-identifier marker (P0...P5) and
frame reference marker.
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
0
Example of JJY data out:
2004 / 92 days (1st April) / 17 hours / 25 minutes
CME8000
“1”
“1”
SPEC No.
(Customer is responsible to verify this information)
Protocol Identifier
minutes
Control Bit
Protocol Bits
5
minutes
0.8s
0.8s
“0”
“0”
1
Time Solutions
10
Revision
B.15
hours
“P”
“1”
0.2s
0.2s
15
Ohtakadoya-yama
40 kHz
50 kW
Hagane-yama
60 kHz
50 kW
hours
2
20
09.03.07
Time frame 1 minute
(Index count 1 second)
25
State
FRM
LS1
LS2
P0-P5
Pa1+Pa2 =
days
0.5 second: Binary one
0.8 second: Binary zero
0.2 second: Position identifier markers P0...P5
3
days
30
Location:
Location:
Geographical coordinates:
Time of transmission:
Geographical coordinates:
Time of transmission:
=
=
=
=
35
03.05.2007
Position identifier markers
Frame marker
Leap second
Leap second
C-MAX printed
Parity bits
4
40
Time-Code Format
The time-code format consists of 1-minute time
frames. A time frame contains BCD-coded
information of minutes, hours, days, weeks and
year. In addition, there are 6 position-identifier
markers (P0 through P5) with reduced carrier
amplitude of 800 ms duration.
year
45
year
5
50
Day
of the
week
day
of
the
week
English
Data Sheet
Version
Miyakoji Vil.,Fukushima Pref.
37° 22'N, 140° 51'E
Fuji Vil., Saga Pref.
33° 28'N, 130° 11'E
55
permanent
permanent
Leap second
6
Leap second
2 3 4
0
Time frame
CME8000
... 0
... 1
5
20 of 22
Page
10

Related parts for CME8000-TLSH