X24-019NSC Digi International/Maxstream, X24-019NSC Datasheet - Page 22

no-image

X24-019NSC

Manufacturer Part Number
X24-019NSC
Description
MOD RF 2.4GHZ 19.2K W/RPSMA CONN
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of X24-019NSC

Frequency
2.4GHz
Data Rate - Maximum
19.2kbps
Modulation Or Protocol
FSK
Power - Output
17dBm
Sensitivity
-110dBm
Voltage - Supply
5V
Current - Receiving
80mA
Current - Transmitting
150mA
Data Interface
PCB, Through Hole
Antenna Connector
RP-SMA
Operating Temperature
0°C ~ 70°C
Package / Case
Module
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Applications
-
Memory Size
-
XStream™ OEM RF Module – Product Manual v5.x00 [2006.02.24] 
CD (DO3 Configuration) Command
CE (Connection Inactivity Timeout) Command
CF (Connection Failure Count) Command
CL (Last Connection Address) Command
CM (Connection Message) Command
<Serial Interfacing> CD Command is used to
redefine the behavior of the DO3 (Data Output
3)/RX LED line.
<Networking & Security> Set/Read the duration
of inactivity that will cause a break in a
connection between modules. The base module
will disconnect when no payload has been
transferred for the time specified by the CE
parameter.
<Diagnostics> Set/Read the number of times the
base module expired retries attempting to send a
Connection Grant Packet. Set to zero to clear the
register.
<Diagnostics/Networking & Security> Read the
address of the remote module that last
connected to the base module. A remote module
will return its DT (Destination Address)
parameter.
<Networking & Security> Select whether base
sends connect messages to the host when a
connection is established. When enabled, a
“CONNECTXXXX” string is sent to the host of the
base module. “XXXX” is the MY (Source Address)
of the connected remote module.
   © 2006 MaxStream, Inc. Confidential and Proprietary 
AT Command: ATCE
Binary Command: 0x34 (52 decimal)
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0x64 (1d second)
Number of bytes returned: 2
Related Commands: CB ( Connection Duration
Timeout), DC (Disconnect), MD (RF Mode)
Minimum Firmware Version Required: 4.30
AT Command: ATCF
Binary Command: 0x35 (53 decimal)
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Minimum Firmware Version Required: 4.30
AT Command: ATCL
Binary Command: 0x39 (57 decimal)
Parameter Range: 0 – 0xFFFF [read-only]
Number of bytes returned: 2
Minimum Firmware Version Required: 4.30
AT Command: ATCM
Binary Command: 0x38 (56 decimal)
Parameter Range: 0 – 1
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.30
AT Command: ATCD
Binary Command: 0x28 (40 decimal)
Parameter Range: 0 – 4
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.2B
Parameter
Parameter
0
1
0
1
2
3
4
[x 10 milliseconds]
addressed to module sent
Assert only when packet
Configuration
Configuration
Default high
Default low
(reserved)
disable
RX LED
enable
22 

Related parts for X24-019NSC