ZALM-301-1C CEL, ZALM-301-1C Datasheet

no-image

ZALM-301-1C

Manufacturer Part Number
ZALM-301-1C
Description
RF TRANSCEIVER
Manufacturer
CEL
Series
Apexr
Datasheet

Specifications of ZALM-301-1C

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
General Purpose
Power - Output
100mW (20dBm)
Sensitivity
-97dBm
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
37mA
Current - Transmitting
170mA @ 100mW
Data Interface
Solder Pad
Antenna Connector
MMCX
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Wireless Frequency
2.4 GHz to 2.5 GHz
Security
128 bit AES
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
DESCRIPTION
Apex modules provide a cost-effective RF transceiver solution for 2.4GHz
ZigBee and IEEE 802.15.4 data links and wireless networks.
The ZALM-301-1 Apex LT module is based on Ember
ZigBee network processor. Also onboard are a 100mW Power Amplifier
and SPI-based microprocessor interface, providing you with the flexibility
to choose an external microprocessor based on your application’s needs.
The APEX LT provide over 4000 feet of range and is designed to deliver
constant RF output power across the 2.1 to 3.6V voltage input, ensuring
consistent performance over the entire life of the battery.
ORDERING INFORMATION
FEATURES
• 1 - 100mW output power, software configured
• Designed for EmberZNet networks
• Miniature footprint: 1.00” x 1.275”
• Integrated PCB trace antenna
• Optional MMCX connector for external antenna
• 16 RF channels (Channel 16 operates at reduced power levels)
• Over 4000 feet of range
• Integrated hardware support for Ember InSight Development
• Non-intrusive debug interface (SIF)
• AES 128 bit encryption
• Low power consumption
• Constant RF output power over 2.1– 3.6 V voltage range
• FCC, IC, and CE certified
• RoHS compliant
Environment
APEX LT MODULE
ZALM-300 Series
The information in this document is subject to change without notice, please confirm data is current.
Document No: 0003-00-07-00-000 (Issue C)
Date Published: April 29, 2010
Part Number
ZALM-301-1
ZALM-301-1C
ZAXM-201-KIT-1
Order Number
Integrated Transceiver Modules for ZigBee / IEEE 802.15.4
Output power 100 mW, PCB Trace Antenna
100 mW Output power, optional MMCX Connector with MMCX Connector for use with off board antenna
Engineering Evaluation Kit (to evaluate the ZALM-301-1 module, please utilize the ZAXM-201-KIT-1)
TM
EM260
DATA SHEET
APEX LT SERIES TRANSCEIVER MODULES
Evaluation Kit available: ZAXM-201-KIT-1
APPLICATIONS
• In meter applications
• Thermostats
• In-home display units
• Security
• HVAC control
• Lighting control
• Thermostats
Automated Meter
Reading
Home &
Building Automation
APEX LT MODULE
ZALM-301-1
Supplying Form
• Ember™ EM260 platform
• Integrated IEEE 802.15.4
• Dedicated network processor
• SPI or UART interface to
• Handles all ZigBee processing &
PHY and MAC
application microcontroller
timing intensive tasks
ZALM-301-1
• Food processing controls
• Traffic Management
• Sensor Networks
• Asset Management
• Barcode reader
• Patient Monitoring
• Glucose monitor
Industrial Controls

Related parts for ZALM-301-1C

ZALM-301-1C Summary of contents

Page 1

... Order Number ZALM-301-1 Output power 100 mW, PCB Trace Antenna ZALM-300 Series ZALM-301-1C 100 mW Output power, optional MMCX Connector with MMCX Connector for use with off board antenna APEX LT MODULE ZAXM-201-KIT-1 Engineering Evaluation Kit (to evaluate the ZALM-301-1 module, please utilize the ZAXM-201-KIT-1) The information in this document is subject to change without notice, please confirm data is current ...

Page 2

... For more detail information regarding Apex Evaluation Kit, refer to the Apex Module Evaluation Kit User Guide document. www.cel.com/pdf/misc/apexseries_ug.pdf) Order Number Description ZAXM-201-KIT-1* Engineering Evaluation Kit • To evaluate the ZALM-301-1 module, please utilize the ZAXM-201-KIT-1 24 MHz XTAL SOC RF Front End (NEC PA and ...

Page 3

... Recommended (Operating Condition).................................................................................................................................................. DC Characteristics.................................................................................................................................................................................. RF Characteristics.................................................................................................................................................................................. Pin Signal & Interfaces Pin Signals I/O Configuration................................................................................................................................................................ Apex LT I/O Pin Assignment.................................................................................................................................................................. Apex LT Module Dimensions................................................................................................................................................................. PCB Copper Pattern Layout................................................................................................................................................................... PCB Stencil Pattern................................................................................................................................................................................ PCB Keep-Out Areas.............................................................................................................................................................................. Processing Agency Certifications Shipment, Storage & Handling References & Revision History ZALM-300 Series ...

Page 4

... In the overall design, ensure that wiring and other components are not placed near the antenna. • Do not place the antenna in a metallic or metallized plastic enclosure. • Keep plastic enclosures more from the antenna in any direction. ZALM-300 Series TOP VIEW TOP VIEW ...

Page 5

... Frequency = 2440 MHz 90 5 120 -10 -15 150 30 -20 -25 -30 180 0 210 330 240 300 270 Vertical Polarization Gain (dBi) min: -24.7 max: -9.6 avg: -14.8 Horizontal Polarization Gain (dBi) min: -8.1 max: +0.4 avg: -3.4 ZALM-300 Series ...

Page 6

... Issuing commands through the SIF interface. In DEEP SLEEP the current consumption of the module will drop to 5.0μA (5.5μA with optional 32.768kHz oscillator en- abled). For more detail information on modes of operation refer to Ember EM260 datasheet available at Ember’s website (www.ember.com) ZALM-300 Series ...

Page 7

... Firmware Download • Product Control and Characterization HOST PROTOCOL INTERFACE COMMANDS For information on Host Protocol Interface Commands and for other software-related documents refer to Ember’s website: http://www.ember.com/products_documentation.html Min Typ Max Unit 0.95 V 0.4 V 0.1 μ µA DD 250 µsec ZALM-300 Series ...

Page 8

... Standby Mode: 10mW 100mW Value Unit 3.6 Vdc V + 0.3, DD Vdc Max 3.6 +10 dBm -45 to 125 °C Min Typ Max 2.1 3.6 2405 2480 - 20 3.3V unless otherwise noted) DD Min Typ 170 37 ZALM-300 Series Unit V MHz ° Max Unit 0 0. μA 5 µA ...

Page 9

... The APEX LT module has a 28 edge I/O interfaces for connection to the user’s host board. Figure 1 shows the layout of the 28 edge castellations. PIN 19 PIN 10 PIN 28 PIN 1 Figure 1 (Top View) = 3.3V unless otherwise noted) DD Min Typ 2400 250 -92 -96 -93 - ZALM-300 Series Max Unit 2483.5 MHz kbps dBm dBm dBm dBm ...

Page 10

... Host Interrupt Signal (from APEX LT to Host) or UART RXD Wake Interrupt Signal (from host to APEX LT) Ground SIF Interface clock SIF Interface master in/slave out SIF Interface master out/slave in SIF Interface load strobe Spare Debug Signal Link and Activity signal Ground Ground Ground Ground PI = Power Input GND = Ground ZALM-300 Series ...

Page 11

... DIMENSIONS: ZALM-301-1 Apex LT Dimensions in inches. Tolerances = +/-0.005” unless otherwise noted. 0.195 RF Shield 0.062 DIMENSIONS: ZALM-301-1C Apex LT with Optional MMCX Connector Dimensions in inches. Tolerances = +/-0.005” unless otherwise noted. 0.195 RF Shield J2 0.062 0.205 Overall Height w/MMCX Connector PIN 19: SIF_CLK SIF_MISO SIF_MOSI ...

Page 12

... PCB PASTE STENCIL PATTERN: Apex LT Dimensions in inches. Tolerances = +/-0.005” unless otherwise noted. 0.065 0.100 Pitch Typ 28 0.900 0.125 Typ 28 Pads 0.040 0.070 Typ 28 Pads PIN 1 Recommended Host PCB Board Edge 0.100 Typ 28 Pads 0.065 0.070 Typ 28 Pads PIN 1 ZALM-300 Series ...

Page 13

... CEL can provide assistance with your PCB layout. Component Keep Out Area: No components within 0.100 inches of module Edge of Host PCB Recommended overhang for PCB Antenna = 0.230 0.050 If module does not overhang edge of host PCB, no components, copper or traces are allowed in this area ZALM-300 Series ...

Page 14

... After soldering the Module to the host board, consider optical inspection to check the following: • Proper alignment and centering of the module over the pads. • Proper solder joints on all pads. • Excessive solder or contacts to neighboring pads, or vias. ZALM-300 Series 3º/sec max 150ºC 200ºC 60-120 sec 217ºC 60-150 sec 260 + 0º ...

Page 15

... Never attempt a rework on the module itself, e.g. replacing individual components. Such actions will terminate warranty coverage. Additional Grounding Attempts to improve module or system grounding by soldering braids, wires, or cables onto the module RF shield cover is done at the customers own risk. The numerous ground pins at the module perimeter should be sufficient for optimum immunity to external RF interference. ZALM-300 Series ...

Page 16

... The APEX module is CE certified. The CE marking must be affixed legibly and indelibly to a visible location on the user’s product. FCC Approved Antennas • Integrated PCB trace antenna • Nearson S131CL-5-RMM-2450S – A 2.4GHz Dipole antenna with a 5 inch cable and a right angle MMCX connector. ZALM-300 Series ...

Page 17

... According to JEDEC ISP, the Apex LT Module is moisture sensitive devices. Appropriate handling instructions and precautions are summarized in Section 2.1. Read carefully to prevent permanent damage due to moisture intake. Moisture Sensitivity Level (MSL) MSL 3, per J-STD-033 ZALM-300 Series ...

Page 18

... To minimize risks of damage to property or injury (including death) to persons arising from defects in CEL products, customers must incorporate sufficient safety measures in their design, such as redundancy, fire-containment and anti-failure features. ZALM-300 Series Page N/A N/A ...

Related keywords