SX1230I066TRT Semtech, SX1230I066TRT Datasheet - Page 24

IC TX UHF 433/868/916 MHZ 24-QFN

SX1230I066TRT

Manufacturer Part Number
SX1230I066TRT
Description
IC TX UHF 433/868/916 MHZ 24-QFN
Manufacturer
Semtech
Datasheet

Specifications of SX1230I066TRT

Frequency
315MHz, 434MHz, 868MHz, 915MHz
Applications
RKE
Modulation Or Protocol
ISM
Data Rate - Maximum
600kbps
Power - Output
17dBm
Current - Transmitting
95mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Voltage - Supply
1.8 V ~ 3.7 V
Operating Temperature
-40°C ~ 85°C
Package / Case
24-MLPQ
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
Product Depth (mm)
4mm
Product Length (mm)
4mm
Operating Supply Voltage (min)
1.8V
Operating Supply Voltage (typ)
2.5/3.3V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Memory Size
-
Lead Free Status / Rohs Status
Supplier Unconfirmed
Other names
Q4629601
SX1230I066TR
SX1230I066TRT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SX1230I066TRT
Manufacturer:
Semtech
Quantity:
42 000
Part Number:
SX1230I066TRT
Manufacturer:
SEMTECH/美国升特
Quantity:
20 000
SX1230, Revision 2 May 2009
©2008 Semtech Corp.
ADVANCED COMMUNICATIONS & SENSING
Addr.
0x0A
0x0B
0x0C
0x0D
0x0E
0x0F
Register Name
PllStat
VcoCtrl1
VcoCtrl2
VcoCtrl3
VcoCtrl4
ClockCtrl
Default
0x10
0x05
NA
NA
NA
NA
Bits
7:6
1:0
7:5
4:0
7:5
4:0
7:5
4:0
7:5
4:0
7:4
2:0
5
4
3
2
3
Variable Name
-
pll_lock_detect
pll_cal_done
pll_cal_ok
pll_cal_start
pll_divr(1:0)
-
SB1(4:0)
-
SB2(4:0)
-
SB3(4:0)
-
SB4(4:0)
-
rc_enable
clkout_select
Page 24
Mode
rw
rw
rw
rw
rw
rw
rw
w
r
r
r
r
r
r
r
r
r
unused
PLL lock status:
0 = PLL not locked
1 = PLL locked
PLL calibration status
0 = Calibration on-going
1 = Calibration performed
Note: Reset to 0 in sleep mode irrespective of
calibration state.
PLL Calibration Result
0 = Calibration procedure failed
1= Calibration procedure successful
Note: Reset to 0 in sleep mode irrespective of
calibration state
Triggers PLL calibration, always read as 0.
PLL division ratio
00 = Automatic
Others, PLL divider = PLL_divr
unused
VCO band first calibration value
unused
VCO band second calibration value
unused
VCO band third calibration value
unused
VCO band fourth calibration value
unused
Enables RC oscillator. RC oscillator is also
automatically switched on in E
0 = RC oscillator off
1 = RC oscillator on
Selects CLKOUT source:
000 = f
001 = f
010 = f
011 = f
100 = f
101 = f
110 = RC clock (65 kHz)
111 = Clock output off.
Note: Switching from RC to f
can generate glitches
XOSC
XOSC
XOSC
XOSC
XOSC
XOSC
Integrated Transmitter IC
/ 2 (16 MHz)
/ 4 (8 MHz)
/ 8 (4 MHz)
/ 16 (2 MHz)
/ 32 (1 MHz) (d)
(32 MHz)
Description
www.semtech.com
DATASHEET
XOSC
SX1230
2
PROM mode.
or vice versa