5. Error Handling
5.1
5.2
4517J–RFID–03/06
Programming
Errors During Writing
Errors Before/During Programming
When all necessary information has been received by the T5557, programming may proceed.
There is a clock delay between the end of the writing sequence and the start of programming.
Typical programming time is 5.6 ms. This cycle includes a data verification read to grant secure
and correct programming. After programming was executed successfully, the T5557 enters
block-read mode transmitting the block just programmed (see
Note:
Several error conditions can be detected to ensure that only valid bits are programmed into the
EEPROM. There are two error types, which lead to two different actions.
The following detectable errors could occur during writing data into the T5557:
If any of these erroneous conditions were detected, the T5557 enters regular-read mode, start-
ing with block 1 of the page defined in the command sequence.
If the command sequence was received successfully, the following error could still prevent
programming:
If the command sequence is validated and the addressed block is not write protected, the new
data will be programmed into the EEPROM memory. The new state of the block write protection
bit (lock bit) will be programmed at the same time accordingly.
Each programming cycle consists of 4 consecutive steps: erase block, erase verification
(data = “0” ), programming, write verification (corresponding data bits = “1”).
• Wrong number of field clocks between two gaps (i.e., not a valid “1” or “0” pulse stream)
• Password mode is activated and the password does not match the contents of block 7
• The number of bits received in the command sequence is incorrect
• The lock bit of the addressed block is set already
• In case of a locked block, programming mode will not be entered. The T5557 reverts to
• If a data verification error is detected after an executed data block programming, the tag will
block-read mode continuously transmitting the currently addressed block.
stop modulation (modulation defeat) until a new command is transmitted.
Valid bit counts accepted by the T5557 are:
Password write
Standard write
AOR wake up
Direct access with PWD
Direct access
Reset command
Page 0/1 regular-read
This timing and behavior is different from the e555x-family predecessors.
70 bits
38 bits
34 bits
38 bits
6 bits
2 bits
2 bits
(PWD = 1)
(PWD = 0)
(PWD = 1)
(PWD = 1)
(PWD = 0)
Figure 4-8 on page