CM400DU-12F Powerex Inc, CM400DU-12F Datasheet
CM400DU-12F
Specifications of CM400DU-12F
Available stocks
Related parts for CM400DU-12F
CM400DU-12F Summary of contents
Page 1
... Applications: £ AC Motor Control £ UPS £ Battery Powered Supplies Ordering Information: Example: Select the complete module number you desire from the table - i.e. CM400DU-12F is a 600V (V CES ), 400 Ampere Dual IGBTMOD™ Power Module. Current Rating V CES Type Amperes Volts (x 50) ...
Page 2
... V iso Symbol Test Conditions I CES CES , GES GES , GE(th 40mA 10V V CE(sat 400A 15V 25° 400A 15V 125° 300V 400A 15V 400A CM400DU-12F Units -40 to 150 °C -40 to 125 °C 600 Volts ±20 Volts 400 Amperes 800* Amperes 400 Amperes ...
Page 3
... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 CM400DU-12F Trench Gate Design Dual IGBTMOD™ 400 Amperes/600 Volts Dynamic Electrical Characteristics 25°C unless otherwise specified Characteristics Input Capacitance Output Capacitance Reverse Transfer Capacitance Inductive Turn-on Delay Time Load Rise Time ...
Page 4
... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 CM400DU-12F Trench Gate Design Dual IGBTMOD™ 400 Amperes/600 Volts OUTPUT CHARACTERISTICS (TYPICAL) 800 25°C 9 20V GE 600 9 400 8.5 200 8 7 COLLECTOR-EMITTER VOLTAGE (VOLTS) CE FREE-WHEEL DIODE FORWARD CHARACTERISTICS (TYPICAL ° 1.0 2 ...