IRKU56/12A Vishay, IRKU56/12A Datasheet

no-image

IRKU56/12A

Manufacturer Part Number
IRKU56/12A
Description
SCR CC 2SCR 1200V 55A ADD-A-PAK
Manufacturer
Vishay
Datasheet

Specifications of IRKU56/12A

Structure
Common Anode - All SCRs
Number Of Scrs, Diodes
2 SCRs
Voltage - Off State
1200V
Current - Gate Trigger (igt) (max)
150mA
Current - On State (it (av)) (max)
60A
Current - On State (it (rms)) (max)
95A
Current - Non Rep. Surge 50, 60hz (itsm)
580A, 890A
Current - Hold (ih) (max)
200mA
Mounting Type
Chassis Mount
Package / Case
ADD-A-PAK (3 + 4)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
*IRKU56/12A
IRKU56/12
IRKU56/12
VS-IRKU56/12A
VS-IRKU56/12A
VSIRKU56/12A
VSIRKU56/12A
THYRISTOR/ THYRISTOR
Mechanical Description
The Generation V of Add-A-pak module combine the
excellent thermal performance obtained by the usage
of Direct Bonded Copper substrate with superior
mechanical ruggedness, thanks to the insertion of a
solid Copper baseplate at the bottom side of the device.
The Cu baseplate allow an easier mounting on the
majority of heatsink with increased tolerance of surface
roughness and improve thermal spread.
The Generation V of AAP module is manufactured
without hard mold, eliminating in this way any possible
direct stress on the leads.
www.irf.com
Major Ratings and Characteristics
Parameters
I
I
I
I
I
V
T
T
T(AV)
T(RMS)
TSM
2
2
Features
High Voltage
Industrial Standard Package
Thick Al metal die and double stick bonding
Thick copper baseplate
UL E78996 approved
3500V
RRM
STG
J
t
t
@ 85°C
@ 50Hz
@ 60Hz
@ 50Hz
@ 60Hz
range
RMS
isolating voltage
IRKU/V41
3.61
3.30
36.1
850
890
45
70
400 to 1600
- 40 to 125
- 40 to125
IRKU/V56
1310
1370
8.50
7.82
85.0
60
95
KA
Units
KA
KA
o
o
A
A
A
A
V
C
C
2
2
2
s
s
s
IRKU/V41, 56 SERIES
Benefits
Up to 1600V
Full compatible TO-240AA
High Surge capability
Easy Mounting on heatsink
Al
Heatsink grounded
These modules are intended for general purpose high
voltage applications such as high voltage regulated power
supplies, lighting circuits, temperature and motor speed
control circuits, UPS and battery charger.
Electrical Description
The electrical terminals are secured against axial pull-out:
they are fixed to the module housing via a click-stop
feature already tested and proved as reliable on other IR
modules.
2
ADD-A-pak
0
3
DBC insulator
TM
Bulletin I27134 rev. E 10/02
GEN V Power Modules
45 A
60 A
1

Related parts for IRKU56/12A

IRKU56/12A Summary of contents

Page 1

THYRISTOR/ THYRISTOR Features High Voltage Industrial Standard Package Thick Al metal die and double stick bonding Thick copper baseplate UL E78996 approved 3500V isolating voltage RMS Mechanical Description The Generation V of Add-A-pak module combine the excellent thermal performance obtained ...

Page 2

IRKU/V41, 56 Series Bulletin I27134 rev. E 10/02 ELECTRICAL SPECIFICATIONS Voltage Ratings Voltage Type number Code peak reverse voltage peak reverse voltage - 04 IRKU/V41 On-state Conduction Parameters IRKU/V41 I Max. average on-state 45 T(AV) current ...

Page 3

Triggering Parameters IRKU/V41 P Max. peak gate power Max. average gate power 2.5 G(AV) I Max. peak gate current 2 Max. peak negative GM gate voltage V Max. gate voltage GT required to trigger I ...

Page 4

IRKU/V41, 56 Series Bulletin I27134 rev. E 10/02 Ordering Information Table Device Code IRK Module type 2 - Circuit configuration (See Circuit Configuration table below Current code * * 4 - ...

Page 5

IRK.41.. Series R (DC) = 0.46 K/W thJC 120 110 Conduction Angle 100 30° 60° 90° 120° Average On-state Current (A) Fig Current Ratings Characteristics 70 180° 60 120° 90° 50 ...

Page 6

IRKU/V41, 56 Series Bulletin I27134 rev. E 10/02 350 300 250 180° (Sine) 200 180° (Rect) 150 100 Single Phase Bridge Total Output Current (A) Fig On-state Power Loss Characteristics (Single Phase Bridge ...

Page 7

RMS Limit Conduction Angle 20 IRK.56.. Series Per Junction 125° Average On-state Current (A) Fig On-state ...

Page 8

IRKU/V41, 56 Series Bulletin I27134 rev. E 10/02 450 400 350 300 I o 250 200 150 100 Connection Bridge 100 Total Output Current (A) Fig On-state Power Loss Characteristics 1000 100 T = ...

Page 9

Steady State Value 0.46 K/W thJC R = 0.40 K/W thJC (DC Operation) 0.1 0.01 0.001 0.01 Fig Thermal Impedance Z 100 Rectangular gate pulse a)Recommended load line for rated di/dt ohms ...

Related keywords