MS5540-CM Measurement Specialties Inc., MS5540-CM Datasheet - Page 3

MODULE BAROMETER MINITURE SENSOR

MS5540-CM

Manufacturer Part Number
MS5540-CM
Description
MODULE BAROMETER MINITURE SENSOR
Manufacturer
Measurement Specialties Inc.
Datasheet

Specifications of MS5540-CM

Pressure Type
Absolute
Operating Pressure
0.15 ~ 0.16 PSI, 10 ~ 1100 mbar
Output
Digital
Voltage - Supply
2.2 V ~ 3.6 V
Termination Style
PCB
Operating Temperature
-40°C ~ 85°C
Package / Case
6.2 x 6.4mm Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
223-1098-2
RECOMMENDED OPERATING CONDITIONS
NOTES
1) Under the assumption of one conversion every second. Conversion means either a pressure or a
2) During conversion the sensor will be switched on and off in order to reduce power consumption; the total on
3) This value can be reduced by switching off MCLK while MS5540C is in standby mode.
4) It is strongly recommended that a crystal oscillator be used because the device is sensitive to clock jitter. A
DA5540C_001
0005540C1193 ECN 1037
Parameter
Operating pressure range
Supply voltage
Supply current,
Current consumption into
MCLK (3)
Operating temperature
range
Conversion time
External clock signal (4)
Duty cycle of MCLK
Serial data clock
average (1)
during conversion (2)
standby (no conversion)
temperature measurement started by a command to the serial interface of MS5540C.
time within a conversion is about 2 ms.
square-wave form of the clock signal is a must.
Symbol
MCLK
SCLK
VDD
t
I
conv
I
I
avg
p
T
sc
ss
February 20th, 2008
MCLK = 32.768 kHz
MCLK = 32.768 kHz
VDD = 3.0 V
Conditions
(
Ta
= 25° C, VDD = 3.0 V unless noted otherwise)
30.000
40/60
Min.
-40
2.2
10
32.768
50/50
Typ.
+25
3.0
4
1
35.000
60/40
1100
Max
+85
500
3.6
0.1
0.5
35
mbar
Unit
abs.
kHz
kHz
mA
ms
µA
µA
µA
° C
%
V
3

Related parts for MS5540-CM