1 INCH-G-4V All Sensors Corporation, 1 INCH-G-4V Datasheet

SENSOR 1" H2O G 4V DUAL

1 INCH-G-4V

Manufacturer Part Number
1 INCH-G-4V
Description
SENSOR 1" H2O G 4V DUAL
Manufacturer
All Sensors Corporation
Datasheet

Specifications of 1 INCH-G-4V

Pressure Type
Gauge
Operating Pressure
0.04 PSI, 1" H20
Port Size
Male, 0.174" ~ 0.19" (4.4mm ~ 4.8mm) Tube, Dual
Output
0.25 ~ 4.25V
Voltage - Supply
4.5 V ~ 5.5 V
Termination Style
PCB
Operating Temperature
-25°C ~ 85°C
Package / Case
4-SIP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
442-1013
Physical Dimensions
Equivalent Circuit
Amplified Low Pressure Sensors
1 mbar (0.4 In H2O) to 30 In H2O Pressure Sensors
General Description
The Amplified line of low pressure sensors is based upon a proprietary technology to reduce all output offset or
common mode errors. This model provides a ratiometric 4-volt output with superior output offset characteris-
tics. Output offset errors due to change in temperature, stability to warm-up, stability to long time period, and
position sensitivity are all significantly reduced when compared to conventional compensation methods. In
addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very
linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide tempera-
ture range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and
the like.
The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.
(27.4)
0.25
(6.4)
1.08
NOTES:
1) Dimensions in inches (millimeters)
(12.2)
0.48
Pin Size
0.010 x 0.020
(0.25 x 0.50)
(14.0)
0.55
0.174 to 0.190
(4.4 to 4.8)
Features
• 0 to 1 mbar to 0 to 30 In H2O Pressure Ranges
• Ratiometric 4V Output
• Temperature Compensated
• Calibrated Zero and Span
Applications
• Medical Instrumentation
• Environmental Controls
• HVAC
1-52
(16.0)
0.66
Pin 1 2 3 4
1
(20.3)
(21.6)
(27.9)
0.80
0.85
1.10
A
B
0.10 Typical
(2.54)
0.21
(5.3)
(10.5)
0.42
pin 1: Vsupply
pin 2: Common
pin 3: Voutput
pin 4: do not
connect

Related parts for 1 INCH-G-4V

1 INCH-G-4V Summary of contents

Page 1

... In H2O H2O Pressure Sensors General Description The Amplified line of low pressure sensors is based upon a proprietary technology to reduce all output offset or common mode errors. This model provides a ratiometric 4-volt output with superior output offset characteris- tics. Output offset errors due to change in temperature, stability to warm-up, stability to long time period, and position sensitivity are all significantly reduced when compared to conventional compensation methods ...

Page 2

... Pressure Sensor Ratings Supply Supply Voltage VS Common-mode pressure Lead Temperature, max (soldering 2-4 sec.) Standard Pressure Ranges Part Number Operating Pressure 1 MBAR-D-4V ±1 mbar 1 INCH-D-4V ±1 In H2O 1 INCH-G- H2O 2.5 INCH-D-4V ±2.5 In H2O 5 INCH-D-4V ± H2O 5 INCH-G- H2O 10 INCH-D-4V ±10 In H2O 10 INCH-G- H2O 20 INCH-D-4V ± ...

Page 3

... Offset Warm-up Shift, note 3 Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5°C-50°C), note 2 Performance Characteristics for 1 INCH-G-4V Parameter, note 1 Operating Range, gage pressure Output Span, note 5 Offset Voltage @ zero pressure Offset Temperature Shift (5°C-50°C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (± ...

Page 4

... NOTE Performance Characteristics for: 10 INCH-D-4V Parameter, 1 NOTE Operating Range, differential pressure Output Span, 5 NOTE Offset Voltage @ zero differential pressure Offset Temperature Shift (5°C-50°C), 2 NOTE Offset Warm-up Shift, 3 NOTE Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Linearity, hysteresis error, ...

Page 5

... Span Shift (5°C-50°C), note 2 Performance Characteristics for 30 INCH-D-4V Parameter, note 1 Operating Range, differential pressure Output Span, note 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (5°C-50°C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5° ...

Page 6

... Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5°C-50°C), note 2 Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than 500 useconds. Specification Notes 1: A 5.0 ...

Related keywords