Specifications of BARO-DO-MIL

Pressure Type
Absolute
Operating Pressure
8.70 ~ 15.95 PSI, 600 ~ 1100 mbar
Port Size
Male, 0.174" ~ 0.19" (4.4mm ~ 4.8mm) Tube, Dual
Output
5V
Voltage - Supply
7V
Termination Style
PCB
Operating Temperature
-40°C ~ 125°C
Package / Case
6-SIP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
442-1098
BARO-DO-MIL
Definitions:
Term
<cr>
<sp>
[Accuracy String]
[hhhh]
[llll]
[Model String]
Command Summary Table:
Command
RA<cr>
RC<cr>
RH<cr>
RL<cr>
RM<cr>
RR<cr>
RS<cr>
RT<cr>
U[S/N String][Command]<cr>
WC<cr>
Notations:
<> indicates a single ascii character
[] indicates an ascii string
“” text within quotes represents a literal ascii text string
{} text within the braces describes the response (this is essentially a comment)
Name
Carriage Return
Space
Accuracy String
High Resolution Output
Low Resolution Output
Model String
Description
Read Accuracy String
Read Captured Pressure
Read High Resolution Pressure
Read Low Resolution Pressure
Read Model
Read Pressure Range
Read Serial Number
Read Temperature
Unique Command
Capture Pressure
4-12
Description
ascii Carrage Return. This is a command/response delimiter
ascii Space Character
Part accuracy string. Given in % full scale output.
Example: 0.250 %FSO
Notes:
This is a four character ascii string representing a
hexidecimal value.
Example: 3F7C
Represents an output count of 16,252
Note: the output is forced to “8000” upon an error.
This is a four character ascii string representing a
hexidecimal value.
Example: 1D58
Represents an output count of 7,512
Note: the output is forced to “8000” upon an error.
Part Model as given in the data sheet (also order number.)
The general model syntax is
[Full Scale Pressure]<sp>[Pressure Units]-[Pressure Model]-DO
Example: 100 PSI-D-DO
Where:
Notes:
Response
RA=[Accuracy String]<cr>
RC=[hhhh]<sp>[eeee]<cr>
RH=[hhhh]<sp>[eeee]<cr>
RL[llll]<sp>[eeee]<cr>
RM=[Model String]<cr>
RR=[pressure Range String]<cr>
RS=[S/N String]<cr>
RT=[Temperature Range String]<cr>
For Matching S/N
For Non-matching S/N {null}
{null}
Full Scale Pressure=100
Pressure Units=PSI (inH2O, mbar or mmHg available)
1.) Exception to this syntax is the Barometer.
2.) Custom models may be different.
1.) There is a space between the numeric accuracy “0.250”
2.) FSO stands for Full Scale Output (full scale output is
except error bit 8, see error bit codes.
except error bit 8, see error bit codes.
DO represents Digital Output
determined by the Pressure Range String.)
and units “%FSO.”
U[S/N String],sp>[Response String]