E8F2-A01B Omron, E8F2-A01B Datasheet

SENSOR PRESSUR 1-5V 0-100KPA PNP

E8F2-A01B

Manufacturer Part Number
E8F2-A01B
Description
SENSOR PRESSUR 1-5V 0-100KPA PNP
Manufacturer
Omron
Series
E8F2r
Type
Gager
Datasheet

Specifications of E8F2-A01B

Pressure Type
Gauge
Operating Pressure
14.50 PSI, 100 kPa
Port Size
Female, 1/8" (3.175mm) NPN
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
0°C ~ 55°C
Package / Case
Module
Output Voltage Range
1 to 5V
Pressure Range
0 to 100KPa
Mounting
Screw
Operating Temp Range
0C to 55C
Operating Temperature Classification
Commercial
Operating Supply Voltage (typ)
15/18V
Operating Supply Voltage (min)
12V
Operating Supply Voltage (max)
24V
Mounting Style
Screw
Maximum Operating Temperature
+ 55 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
15 V, 18 V
Output Voltage
1 V to 5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E8F2A01B
Pressure Sensor with
Easy-to-Read LED Display
• Pressure status can be checked at a glance from the red
• Measurement pressure is averaged by the chattering
• The automatic teaching function teaches pressure
• Industry’s smallest models at just 28 × 28 × 29 mm.
Ordering Information
Sensors
Accessories (Order Separately)
digital pressure value and analog bar displays.
prevention function to prevent incorrect outputs due to
momentary pressure changes.
values for good and bad products.
Negative pressure
Digital Pressure Sensor
E8F2
Positive pressure
Appearance
Be sure to read Safety Precautions
on page 6.
Pressure range
Mounting Bracket E89-F3
Panel-mounting
Bracket
0 to −101 kPa
0 to 100 kPa
Name
0 to 1 MPa
E89-F4
Open collector
(two independent outputs)
Model
ON/OFF output
Provided with the E8F2.
Spacer provided.
Remarks
Linear output
1 to 5 V
E8F2-A01C
E8F2-B10C
E8F2-AN0C
NPN output
Model
E8F2-A01B
E8F2-B10B
E8F2-AN0B
CSM_E8F2_DS_E_3_1
PNP output
1

Related parts for E8F2-A01B

E8F2-A01B Summary of contents

Page 1

... Negative pressure Accessories (Order Separately) Appearance Name Mounting Bracket E89-F3 Panel-mounting E89-F4 Bracket ON/OFF output Linear output Open collector (two independent outputs) Model Remarks Provided with the E8F2. Spacer provided. CSM_E8F2_DS_E_3_1 Model NPN output PNP output E8F2-A01C E8F2-A01B E8F2-B10C E8F2-B10B E8F2-AN0C E8F2-AN0B 1 ...

Page 2

... E8F2-AN0C Note: The period ( ) in the display indicates the decimal point. Its position will not change unless the setting unit is changed. E8F2-A01C E8F2-B10C E8F2-A01B E8F2-B10B MPa MPa 1.5 MPa −10 to 60°C (with no icing times each in the X, Y, and Z directions ...

Page 3

... Temperature vs. Linear Output Current Fluctuation E8F2-A01@ +10 +5 Rated pressure Pressure 0 0 −5 −10 − Temperature (˚C) Pressure vs. Linear Output E8F2-A01 100 Pressure (kPa) Temperature vs. Operating Pressure Fluctuation E8F2-A01@ + −5 −10 − Temperature (˚C) Linearity E8F2-A01@ +1 +0.5 0 −0.5 − 100 Pressure (kPa) E8F2 3 ...

Page 4

... OFF PNP Output Oper- ating Model Hysteresis mode mode Pressure ON point OFF point NO ON Output OFF OUT ON indicator (orange) OFF E8F2-A01B E8F2-B10B E8F2-AN0B Pressure ON point OFF point NC ON Output OFF OUT ON indicator (orange) OFF Timing chart Window mode Pressure OFF point OFF point − ...

Page 5

... Use together with the SET Key for setting the Sensor to a special setting mode or energy-saving mode. (8) SET Key SET • Used for entering the set contents and set values in setting mode. • Used for setting the Sensor to basic setting mode or pressure setting mode. E8F2 5 ...

Page 6

... Ratings and Specifications. • Turning ON the power The Sensor is ready to operate 0.5 s after it is turned ON. When the load and Sensor are connected to separate power supplies, be sure to turn ON the Sensor first. ● Others Make sure the Sensor does not get wet. E8F2 6 ...

Page 7

... Dimensions Sensors E8F2 Display panel With Mounting Bracket Attached Accessories (Order Separately) Mounting Bracket E89-F3 15 13.5 26.9 90˚ ±0. 5 Note: Provided with the E8F2. R1.6 max. 28 (29 20.5 4-dia. vinyl-insulated round cable with 5 conductors (Conductor cross-section: 0.15 mm Standard length 20.5 9 ± ...

Page 8

... Panel Cutout Dimensions 20.65 Spacer Not Mounted 12.15 +0 Panel* Panel 11.5 * Applicable panel thickness: 1 Note: The spacer can be removed from the Panel-mounting Bracket. The panel cutout dimensions can be adjusted as shown above by attaching or detaching the spacer. E8F2 Spacer Mounted +0 +0 41.3 Spacer 8 ...

Page 9

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...