E8Y-A2C-RD Omron, E8Y-A2C-RD Datasheet

SENSOR PRESSUR DIFF 0-.29PSI NPN

E8Y-A2C-RD

Manufacturer Part Number
E8Y-A2C-RD
Description
SENSOR PRESSUR DIFF 0-.29PSI NPN
Manufacturer
Omron
Series
E8Yr
Type
Differentialr
Datasheets

Specifications of E8Y-A2C-RD

Pressure Type
Differential
Operating Pressure
0.29 PSI
Port Size
Male, 1/8" (3.175mm) Pipe Threads
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
-10°C ~ 55°C
Package / Case
Module
Output Voltage Range
1 to 5V
Pressure Range
0 to 0.29Psi
Mounting
Panel
Operating Supply Voltage (typ)
15/18V
Operating Supply Voltage (min)
12V
Operating Supply Voltage (max)
24V
Sensor Output
Transistor
External Depth
30mm
Voltage Rating
24V
Port Style
PT
Pressure Measurement Type
Differential
Operating Pressure Range
0-0.29 Psi
Sensing Accuracy
0.1%
No. Of Ports
2
Accuracy
+/- 3 %
Mounting Style
Panel
Operating Supply Voltage
12 V to 24 V
Output Voltage
1 V to 5 V
Pressure Port
Y
Sensor Type
Sensors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E8YA2CRD
E8Y
"Cube" Type Differential Pressure
Sensor with LED Display Offers High
Precision Sensing
Ordering Information
Type
Flow sensor
Description
Panel-mounting bracket
Miniature
differential
pressure
sensor
Differential Pressure Sensor
New psi version available
Compact, cube-style measuring 31 x 30
x 30 mm (1.22 x 1.18 x 1.18 in) saves
mounting space
Easy-to-read red LEDs
Digital and analog output available
Flow sensing type available
PNP output types available upon special
request
SENSOR
ACCESSORIES
Digital output
NPN open collector
(2 independent outputs)
Analog output
4 to 20 mA
Pressure range
0 to 2.0 kPa
0 to 5.0 kPa
0 to 0.290 psi
0 to 0.725 psi
0 to 2.0 kPa
0 to 5.0 kPa
0 to 0.290 psi
0 to 0.725 psi
0.3 to 3.0 liter/min.
(0.07 to 0.68 gal./min.)
2.0 to 20 liter/min.
(0.45 to 4.54 gal./min.)
2
Port/Mounting
4.5 mm dia. pipe
1/8 NPT
4.5 mm dia. pipe
1/8 NPT
4.5 mm dia. pipe
1/8 NPT
4.5 mm dia. pipe
1/8 NPT
4.5 mm dia. pipe
1/8 NPT
4.5 mm dia. pipe
1/8 NPT
4.5 mm dia. pipe
1/8 NPT
4.5 mm dia. pipe
1/8 NPT
1/8 NPT, vertical
1/8 NPT, horizontal
1/8 NPT, vertical
1/8 NPT, horizontal
Part number
E8Y-A2C
E8Y-A2C-R
E8Y-A5C
E8Y-A5C-R
E8Y-A2C-D
E8Y-A2C-RD
E8Y-A5C-D
E8Y-A5C-RD
E8Y-A2Y
E8Y-A2Y-R
E8Y-A5Y
E8Y-A5Y-R
E8Y-A2Y-D
E8Y-A2Y-RD
E8Y-A5Y-D
E8Y-A5Y-RD
E8Y-A5C-F03V
E8Y-A5C-F03H
E8Y-A5C-F20V
E8Y-A5C-F20H
Part number
E89-Y1
E8Y
E8Y

Related parts for E8Y-A2C-RD

E8Y-A2C-RD Summary of contents

Page 1

... E8Y-A2C 1/8 NPT E8Y-A2C-R 4.5 mm dia. pipe E8Y-A5C 1/8 NPT E8Y-A5C-R 4.5 mm dia. pipe E8Y-A2C-D 1/8 NPT E8Y-A2C-RD 4.5 mm dia. pipe E8Y-A5C-D 1/8 NPT E8Y-A5C-RD 4.5 mm dia. pipe E8Y-A2Y 1/8 NPT E8Y-A2Y-R 4.5 mm dia. pipe E8Y-A5Y 1/8 NPT E8Y-A5Y-R 4 ...

Page 2

... E8Y Specifications RATINGS/CHARACTERISTICS Item E8Y-A2C E8Y-A2C-R E8Y-A2C-D E8Y-A2C-RD Sensor type Differential pressure sensor Power supply voltage VDC 10%, ripple (p-p) 10% max. Current consumption 50 mA max. Pressure type Differential pressure Rated pressure / 0 to 2.0 kPa volume range 0 to 0.29 psi Withstand pressure / 50 kPa (7.25 psi) ...

Page 3

... E8Y Application Examples DETECTION OF EXHAUST FAN FILTER ROTATION CLOGGING DETECTION Filter E8Y Nomenclature E8Y PRESSURE SENSOR 3 3 x10- psi Display 1 Numerical value/menu indication Displays the measured pressure and some menu settings. 2 Unit Shows the measuring unit. Unit currently in use is illuminated. 3 OUT 1 indication LED In measurement mode, it lights when OUT 1 output is on ...

Page 4

... E8Y Operation FUNCTIONS Function Description Pressure units Switches between mmH2O and kPa, excluding the E8Y- -F switching Comparitive ON/ Two independent outputs can be set. OFF output (two (1) Output mode (mode is automatically determined from the ON and OFF point set values.) independent Hysteresis mode: outputs If ON point point set value > ...

Page 5

... This error is automatically reset when the supplied value enters the rated range. (5) ON/OFF point input error warning: Indicates if the difference between the ON point and OFF point in the window mode exceeds the hysteresis value + setting resolution (0.01 kPa/1 mmH Hysteresis width Window width Pressure value OFF point O E8Y ...

Page 6

... CONTROLLER OF PRESSURE SENSOR Standard Port (Pressure Port 4.5 dia.) Type E8Y-A2C E8Y-A5C E8Y-A2Y E8Y-A5Y E8Y-A2C-D E8Y-A5C-D E8Y-A2Y-D E8Y-A5Y-D Die-cast Port (Pressure Port Rc(PT) 1/8) Type E8Y-A2C-R E8Y-A5C-R E8Y-A2Y-R E8Y-A5Y-R E8Y-A2C-RD E8Y-A5C-RD E8Y-A2Y-RD E8Y-A5Y-RD Brown 100 Load mA max. OUT1 Black 100 mA Load max. ...

Page 7

... Two-3.7 dia. Two-3.7 (0.15) dia. 22 (0.87) 26 (1.02) 22 (0.87) Provided with E8Y 31 (1.22) 41.3 (1.63) 13 dia. 67.3 (2.65) 47.3 (1.86) 5 (0.20 (78.7) (1.18) 30 (1.18) Two-1/8 NPT Two-Rc (PT) taper screw 1/8 taper screw 10 (0 ...

Page 8

... With Mounting 45 Panel 48 48 (1.89) +0 +0.02 (1. +0 +0.02 (1.89) (1. Panel (DIN size) Holder Frame Guide Cover 9 E8Y 6 4 (0.24) (0.16) 38.8 (1.53) 15 (0.59) 30.9 (1.22) 57 (2.24) 10.8 (0.43 (0.31) (0.24) 36.8 (1.45) 15 (0.59) 28.9 (1.14) 8.8 (0.35) Holder (Panel) 57 (2.24) ...

Page 9

... OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.com/oci Specifications subject to change without notice. E8Y OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in the U.S.A. ...