P51-2000-S-L-I36-4.5V SSI Technologies Inc, P51-2000-S-L-I36-4.5V Datasheet - Page 2

no-image

P51-2000-S-L-I36-4.5V

Manufacturer Part Number
P51-2000-S-L-I36-4.5V
Description
SENSOR 2000PSI M10-1.25 6H 4.5V
Manufacturer
SSI Technologies Inc
Series
MediaSensor™r
Datasheet

Specifications of P51-2000-S-L-I36-4.5V

Pressure Type
Sealed Gauge
Operating Pressure
2000 PSI
Port Size
Female, M10-1.25 6H
Output
0.5 ~ 4.5V
Accuracy
±0.5%
Voltage - Supply
5V
Termination Style
Cable 3'
Operating Temperature
-40°C ~ 105°C
Package / Case
Stainless Steel
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Standard Full Scale Pressure Ranges
Measurement Technology
In general, pressure measurement technology translates
force from an induced pressure into an electrical quantity.
The MediaSensor™ family of pressure transducers and
transmitters use piezoresistive technology for its sensor
signal processing to measure pressure.
A micro-machined stainless steel convoluted diaphragm
with a silicon crystal semiconductor is used. Strain gauges
(resistive elements) in the silicon crystal are used in a
Wheatstone Bridge circuit. When pressure is applied, the
resistivity of the strain gauges changes proportional to the
pressure applied. Since a single silicon crystal is used it
has a low mechanical hysteresis with good linearity.
One leg of the bridge measures the input pressures port.
The other leg of the bridge is connected to the reference
port the input pressure port is compared to. The connection
to this reference port determines the pressure sensing
convention used.
The MediaSensor™ family comes in a choice of three
pressure sensing type conventions: absolute, gauge
(vented or sealed).
SSI TECHNOLOGIES, INC.
Controls Division
2643 W. Court Street
Janesville, WI 53548-5011
Phone: (608)758-1500 Fax: (608) 758-2491
www.ssitechnologies.com
Gage: 3, 5,10, 15, 25, 30, 50, 60, 75, 100, 120, 130,
200, 225, 250 and 300 PSIG
Sealed: 50, 100, 150, 200, 300, 400, 500, 750, 1000,
1500, 2000, 3000 and 5000 PSIS
Absolute: 15, 30, 50, 65, 75, 100, 150, 200, 250, 300,
500, 750, 1000, 1500, 2000, and 3000 PSIA
MediaSensor™ Absolute, Sealed, Gage Pressure Sensors
SSI Technologies – Application Note PS-AN2
Family Product Overview
Page 2
Absolute MediaSensors™ measure pressure relative to
perfect Vacuum pressure (0 PSI) which remains unchanged
regardless of temperature, location or other ambient
conditions such as weather. Absolute MediaSensors™ are
calibrated to have 0.5 Vdc, 1 Vdc, or 4 mA respectively at 0
PSIA.
There are two different gauge pressure conventions –
Vented Gauge and Sealed Gauge. Gauge MediaSensors™
measure pressure relative to ambient room pressure
through a port that is vented (open) to the atmosphere.
Gauge MediaSensors™ are calibrated to have 0.5 Vdc, 1
Vdc, or 4 mA respectively at 0 PSIG.
Sealed MediaSensors™ measure pressure relative to a port
that is connected to a sealed perfect vacuum chamber.
Sealed MediaSensors™ are calibrated to 14.5 PSI
absolute. Sealed MediaSensors™ are calibrated to have
0.5Vdc, 1 Vdc, or 4 mA respectively at 14.5 PSIA.
The MediaSensor™ takes the two voltage output ports of
the
Piezoresistive pressure sensors are sensitive to changes in
temperature. The MediaSensor™ uses signal conditioning
to compensate for temperature and calibration. The output
signal is then converted into one of four forms:
1) 0.5 – 4.5 Volt ratiometric output (transducer)
2) 0.5 – 4.5 V ratiometric output with Overvoltage
3) 1 – 5 volt output (transducer)
4) 4 – 20 mA output (transmitters)
Wheatstone
protection (transducer)
bridge
Copyright January 12, 2009
and
SSI Technologies Inc.
All Rights Reserved
Revision 3
amplifies
RoHS
the
signal.