A22N-MR100 Omron, A22N-MR100 Datasheet - Page 44

no-image

A22N-MR100

Manufacturer Part Number
A22N-MR100
Description
AUTO-MAN
Manufacturer
Omron
Datasheet

Specifications of A22N-MR100

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
A22NMR100
To easily remove the Snap-in Legend Plate from the Legend
Plate Frame mounted to the panel, insert a Tool with a thin tip
into the space between the Snap-in Legend Plate and the
Legend Plate Frame.
The Snap-in Legend Plate is easily removed by pressing the
Snap-in Legend Plate from the back of the Legend Plate Frame.
The Legend Plate Frame is made of acrylic resin, which is easily
damaged by shock. Be sure to handle the Legend Plate Frame
with care.
Precautions
J CORRECT USE
Mounting
Always make sure that the power is turned OFF before mounting,
removing, or wiring the Switch, or performing maintenance.
Do not tighten the mounting ring more than necessary using tools
such as pointed-nose pliers. Doing so will damage the mounting ring.
The tightening torque is 0.98 to 1.96 N • m {10 to 20 kgf • cm}.
The panel thickness is 1 to 5 mm.
Common To All Assemblies
Do not apply a voltage between the incandescent lamp and
the terminal that is greater than the rated voltage. If the incan-
descent lamp is broken, the Operational Units may pop out.
Always turn OFF the power and wait for 10 minutes before
replacing the incandescent lamp. If the lamp is replaced
immediately after the power is turned OFF, the remaining heat
may cause burns.
!
WARNING
45
J ENGRAVING METHOD
Material: Acrylic
Engrave the characters directly on the matted side of the Snap-in
Legend Plate.
The characters must be engraved no deeper than 0.5 mm.
Apply alcohol-based paint coating to the engraved characters.
If the Snap-in Legend Plate is transparent, engrave the
mirror-written characters on the back of the Snap-in Legend Plate
and apply paint coating to the characters. Then apply paint
coating of a different color to the remaining part of the Snap-in
Legend Plate.
J MOUNTING THREE-THROW SPACER
Press and secure the two protruding portions of the Three-throw
Spacer to the two indented portions of the inner side of the
control panel.
Wiring
After wiring the Switch, maintain an appropriate clearance and
creepage distance.
When DC-specific LEDs are used, wire the Switch so that the X1
terminal is positive.
Terminal screws must be Phillips or slotted M3.5 screws with a
square washer.
The tightening torque is 1.08 to 1.27 N • m {11 to 13 kgf • cm}.
Single wires, stranded wires, and crimp terminals can be
connected to the Switch.
Operating Environment
The IP65 model is designed with a protective structure so that it
will not sustain damage if it is subjected to water from any
direction to the front of the panel.
Common To All Assemblies