RI-70CTA Coto Technology, RI-70CTA Datasheet - Page 2

SWITCH MAGNETIC .5A 7-14AT

RI-70CTA

Manufacturer Part Number
RI-70CTA
Description
SWITCH MAGNETIC .5A 7-14AT
Manufacturer
Coto Technology
Series
RI-70r
Type
Glass Bodyr
Datasheet

Specifications of RI-70CTA

Circuit
SPST-NO
Must Operate
7 ~ 14AT
Switching Current (dc) (max)
500mA
Switching Voltage (dc) (max)
170V
Switching Power (max)
10W
Magnet
Not Specified
Mounting Type
Non-Standard (Axial)
Termination Style
Axial (2 Leads)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Must Release
-
Other names
306-1077
RI-70
RI-70GP0715
Mechanical Data
Contact arrangement is normally open; lead finish is
tinned; net mass is approximately 70 mg; and can be
mounted in any position.
Shock
The switches are tested in accordance with “IEC 68-2-
27”, test Ea (peak acceleration 100 G, half sinewave;
duration 11 ms). Such a shock will not cause an open
switch (no magnetic field present) to close.
Vibration
The switches are tested in accordance with “IEC 68-2-
26”, test Fc (acceleration 10G; below cross-over fre-
quency 57 to 62 Hz; amplitude 0.75 mm; frequency
range 10 to 2000 Hz; duration 90 minutes.) Such a
vibration will not cause an open switch (no magnetic
field present) to close, nor a switch kept closed by an
80 AT coil to open.
Mechanical Strength
The robustness of the terminations is tested in accor-
dance with “IEC 68-2-21”, test Ua
RI-70 Series Dry Reed Switch
For Most Recent Data, Consult the Coto Technology Website:
1
(load 10 N).
www.cotorelay.com
O
Operating ambient temperature; min: -55°C;
max:
+
may be permissible. For more information contact your
nearest Coto Technology sales office.
Soldering
The switch can withstand soldering heat in accordance
with “IEC 68-2-20”, test Tb, method 1B: solder bath at
350 ±10° C for 3.5 ±0.5 s. Solderability is tested in
accordance with “IEC 68-2-20” test Ta, method 3:
solder globule temperature 235°C; ageing 1b: 4 hours
steam.
Welding
The leads can be welded.
Mounting
The leads should not be bent closer than 1 mm to the
glass-to-metal seals. Stress on the seals should be
avoided. Care must be taken to prevent stray magnetic
fields from influencing the operating and measuring
conditions.
125°C. Note: Temperature excursions up to 150°C
perating and Storage Temperature
+
125°C. Storage temperature; min: -55°C; max:
6
E-mail: sales@cotorelay.com
101

Related parts for RI-70CTA