JWL11RA1A NKK Switches, JWL11RA1A Datasheet - Page 9

SWITCH ROCKER SPST 16A BLACK

JWL11RA1A

Manufacturer Part Number
JWL11RA1A
Description
SWITCH ROCKER SPST 16A BLACK
Manufacturer
NKK Switches
Series
JWr
Type
Internationally Approved TV Rated Rockersr
Datasheet

Specifications of JWL11RA1A

Circuit
SPST
Switch Function
On-Off
Contact Rating @ Voltage
16A @ 125VAC
Illumination
Non-Illuminated
Mounting Type
Panel Mount, Snap-In
Termination Style
Solder, Quick Connect - .187" (4.7mm)
Panel Cutout Dimensions
29.50mm x 20.50mm
Contact Form
SPST
Contact Rating
16 Amps at 125 Volts
Actuator
Rocker
Color
Black
Mounting Style
Panel
Terminal Seal
Epoxy
Contact Plating
Silver
Features
Combination of dust cover, housing, actuator, pivot provides protection for contacts
Voltage Rating Ac
250 VAC
Pole Throw Configuration
SPST
Switch Configuration
ON None OFF
Actuator Style
Rocker
Actuator Material
Polyphenylene Ether
Current Rating (max)
16A
Illumination Type
Not Required
Ac Voltage Rating (max)
250VVAC
Dc Voltage Rating (max)
72VVDC
Mechanical Life
25000
Contact Material
Silver Alloy
Housing Material
Melamine/Polyamide
Product Height (mm)
36.5mm
Product Depth (mm)
23mm
Operating Temp Range
-25C to 70C
Terminal Type
Quick Connect/Solder
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Illumination Type, Color
-
Illumination Voltage (nominal)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
360-1491
B
Series JW
B48
Operating Environment
• Do not install switch where heavy dust collection occurs. Dust build-up under rocker may affect switch actuation.
• Do not actuate switch if submerged in water or oil.
• Installation is not recommended on horizontal surface in an environment where frequent splashing of
Panel Mounting
• Before snapping a switch into the panel, align the gasket evenly under bezel of the switch.
• When mounting into a panel, apply equal pressure to sides of bezel and insert parallel to panel.
• After mounting a switch, be sure there are no gaps between switch and panel.
• After installing into panel, do not apply excessive force.
• After panel installation and wiring is completed, do not apply force horizontally
• Behind the panel, cut area should be squared. If front of panel is painted, do not allow any paint to collect in
• Avoid reinstalling a switch once it has been mounted in a panel. This may cause deterioration of panel sealability.
water may occur. In such an environment, a minimum 30° angle installation is advisable. If there is
a possibility of freezing, install vertically so no moisture will be retained within switch housing.
Lightly push into panel.
or vertically from behind panel.
corners of cutout to prevent level mounting.
PRECAUTIONS FOR HANDLING & STORAGE FOR JWMW/LW (PANEL SEAL TYPES)
www.nkk.com
High Inrush 10 & 16 Amp Rockers
Incorrect
Correct
Clean Edges
30°

Related parts for JWL11RA1A