V-15G3-1C26-K Omron, V-15G3-1C26-K Datasheet - Page 6

SWITCH LEVER LONG SPDT 15A

V-15G3-1C26-K

Manufacturer Part Number
V-15G3-1C26-K
Description
SWITCH LEVER LONG SPDT 15A
Manufacturer
Omron
Series
Vr
Type
Snap Actionr
Datasheets

Specifications of V-15G3-1C26-K

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
15A @ 250VAC
Actuator Type
Lever, Straight
Mounting Type
Chassis Mount
Termination Style
Quick Connect - .187" (4.7mm)
Operating Force
130gf
Contact Form
SPDT
Contact Rating
15 Amps at 250 Volts
Actuator
Lever, Hinge
Microswitch Type
Miniature
Actuator Style
Hinge Lever
Operating Force Max
400gf
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
250V
Contact Current Max
15A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
SW134
V15G31C26K
■ Characteristics
Note: 1. Data shown are of initial value.
■ Contact Specifications
Note: Minimum applicable loads are indicated by N standard reference values. This value represents the failure rate at a 60%
126
Operating speed
Operating frequency
Insulation resistance
Contact resistance
Dielectric strength (see note 2)
Vibration resistance (see note 3)
Shock resistance (see note 3)
Life expectancy
Degree of protection
Degree of protection against electric shock Class I
Proof tracking index (PTI)
Ambient operating temperature
Ambient operating humidity
Weight
Contact
Inrush current
Minimum applicable load
2. The dielectric strength shown is measured using a separator between the switch and metal mounting plate.
3. For pin plunger models, the above values apply for use at both the free position and total travel position. For lever models, they apply at
4. For testing conditions, contact your OMRON sales representative.
(JIS C5003). The equation
level of 60%
the total travel position.
Snap Action Switch
Item
Specification
Material
Gap
(standard value)
NC
NO
λ
60
=0.5 x 10
V
-6
0.1 mm to 1 m/s (plunger models)
Mechanical: 600 operations/minute, max.
Electrical: 30 operations/minute, max.
100 MΩ min. (at 500 VDC)
15 mΩ max.
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
V-21, V-16 and V-11:
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between
each terminal and non-current-carrying metal parts
V-15 and V-10:
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between
each terminal and non-current-carrying metal parts
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s
Malfunction:
Mechanical: 50,000,000 operations min. (60 operations/minute)
Electrical: V-21/V-16/V-15:
IEC IP40
175
-25°C to 80°C (at 60% RH max.) with no icing
-25°C to 150°C for heat resistive models (at 60% RH max.) with no icing.
85% max. (for 5°C to 35°C)
Approx. 6.2 g (plunger models)
/ operations indicates that a failure rate of 1/2,000,000 operations can be expected at a reliability
50 A max.
V-21
V-11/V-10:
V-21/V-16/V-15:
V-11/V10:
40 A max.
2
(approx. 100G) max.
V-16
1 mm (F gap type) or 0.5 mm (G gap type)
100,000 operations min. (30 operations/minute)
(V-15 heat resistive: 20,000 operations min. (30 ops/minute))
(V-10 heat resistive: 50,000 operations min. (30 ops/minute))
300,000 operations min. (30 operations/minute)
Silver alloy
160 mA at 5 VDC
300 m/s
200 m/s
36 A max.
Rivet
V-15
2
2
(approx. 30G) max.
(approx. 20G) max.
V-11
24 A max.
60
) reliability level
Silver
V-10

Related parts for V-15G3-1C26-K