D3V-16G4-1C25-K Omron, D3V-16G4-1C25-K Datasheet - Page 6

SWITCH LEVER SPDT 16A .187" QC

D3V-16G4-1C25-K

Manufacturer Part Number
D3V-16G4-1C25-K
Description
SWITCH LEVER SPDT 16A .187" QC
Manufacturer
Omron
Series
D3Vr
Type
Basicr
Datasheets

Specifications of D3V-16G4-1C25-K

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
16A @ 250VAC
Actuator Type
Lever, Simulated Roller
Mounting Type
Chassis Mount
Termination Style
Quick Connect - .187" (4.7mm)
Operating Force
200gf
Microswitch Type
Miniature
Actuator Style
Simulated Roller Lever
Operating Force Max
200gf
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
250V
Contact Current Max
16A
Body Style
Miniature
Brand/series
D3V Series
Contact Form
SPDT
Current, Rating
16 A
Dielectric Strength
2000 VAC
Ip Rating
IP00
Mounting Hole Size
2.9 mm
Number Of Poles
1
Operation
Snap Action
Standards
UL Listed, CSA Certified
Temperature, Operating
+125 °C
Termination
Quick Connect
Voltage, Rating
250 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
D3V16G41C25K
SW703
Specifications
■ Ratings
Note: 1. The above current values are the normal current values of models with a contact gap of 1 mm (gap F), which vary with the normal current
■ Approved Standards
UL1054 (File No. E41515)
CSA C22.2 No.55 (File No. LR21642)
(Only standard ratings are listed.)
EN 61058-1: 1992+A1: 1993 (License No. 119151L)
Testing conditions: 50,000 operations, T85 (0°C to 85°C) for D3V-21/D3V-01, T105 (0°C to 105°C) for D3V-16/D3V-11/D3V-6 and T200
(0 to 200°C) for D3V-6/-01 with suffix “T”, T155 (0 to 155°C) for D3V-11 with suffix “T”.
**Testing conditions: 10,000 operations, T85 (0°C to 85°C)
EN 60695-2-11 Ed.2, EN 60695-2-12 Ed.2 - - Glow-wire flammability test methods
78
D3V-21
D3V-16
D3V-11
D3V-6
D3V-01
125 VAC
250 VAC
125 VDC
250 VDC
125 VAC
250 VAC
250 VAC
125 VAC
250 VAC
Rated voltage
Rated voltage
Rated voltage
Type
2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The ratings values apply under the following test conditions: Ambient temperature: 20±2°C, Ambient humidity: 65±5%, Operating frequency: 30 operations/min
values of models with a contact gap of 0.5 mm (gap G).
Miniature Basic Switch
250 VAC
8 VDC
30 VDC
125 VDC
250 VDC
250 VAC
8 VDC
30 VDC
125 VDC
250 VDC
250 VAC
8 VDC
30 VDC
125 VDC
250 VDC
250 VAC
8 VDC
30 VDC
125 VDC
250 VDC
125 VAC
8 VDC
30 VDC
Rated voltage
20.1 A, 3/4 HP 16 A, 1/2 HP
D3V-21G
3/4 HP
---
---
21 (8) A**
D3V-21G
20 (4) A
---
16 (3) A
D3V-16
---
16 A, 1/2 HP
D3V-16
0.6 A
0.3 A
NC
Resistive load
D3V
0.6 A
0.3 A
0.6 A
0.3 A
0.6 A
0.3 A
0.4 A
0.3 A
0.1 A
0.1 A
0.1 A
21 A
21 A
14 A
16 A
16 A
10 A
11 A
11 A
6 A
6 A
6 A
6 A
16 A, 1/2 HP
16 A, 1/2 HP
16 (3) A
D3V-16
Non-inductive load
D3V-16G
NO
---
0.1 A
---
11 (3) A
D3V-11
---
11 A, 1/2 HP
11 A, 1/2 HP
NC
D3V-11
Lamp load
0.6 A
0.3 A
0.05 A
0.05 A
0.05 A
0.05 A
0.1 A
0.1 A
1.5 A
0.1 A
0.1 A
3 A
5 A
5 A
2 A
4 A
4 A
3 A
3 A
3 A
3 A
3 A
---
---
11 (3) A
D3V-11
---
NO
11 A, 1/2 HP
11 A, 1/2 HP
D3V-11G
0.1 A
---
6 (2) A
D3V-6
NC
Inductive load
---
6 A, 1/4 HP
6 A, 1/4 HP
0.6 A
0.3 A
0.6 A
0.3 A
0.6 A
0.3 A
0.4 A
0.2 A
12 A
12 A
12 A
10 A
10 A
10 A
6 A
6 A
6 A
4 A
4 A
4 A
D3V-6
---
---
6 (2) A
D3V-6
---
---
---
NO
Inductive load
6 A, 1/4 HP
6 A, 1/4 HP
D3V-6G
---
---
NC
D3V-01
Motor load
0.1 A
0.05 A
0.05 A
0.05 A
---
D3V-01
0.1 A
0.1 A
0.1 A
0.1 A
4 A
7 A
5 A
3 A
6 A
4 A
2 A
3 A
3 A
---
---
---
---
---
D3V-01
0.1 A
---
---
---
NO

Related parts for D3V-16G4-1C25-K