SWITCH ROLLER ARM LEVER SPDT 15A

ZV2-NA2-2S

Manufacturer Part Number
ZV2-NA2-2S
Description
SWITCH ROLLER ARM LEVER SPDT 15A
Manufacturer
Omron
Series
ZV2r
Datasheet

Specifications of ZV2-NA2-2S

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
15A @ 125VAC
Actuator Type
Lever, Roller
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
726gf
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
ZV2NA22S
General-purpose Enclosed
Switches with High Breaking
Capacity and High Durability
• Z General-purpose Basic Switches are built into ZE, ZV,
• X Basic Switches with magnetic blowout are built into XE,
• Three mounting methods (side, base, and diagonal side)
• Terminals face the front when the cover is removed for
• Switches with ground terminals have CE marking.
• Approved by UL, CSA, and CCC (Chinese standard).
Model Number Structure
Model Number Legend
(1) Built-in Switch
(2) Mounting Direction
* Consult with your OMRON representative concerning availability, pricing, and delivery of conduit sizes and ground terminal specifications other than those on standard
models.
(1) (2) (3)
and ZV2 Switches. They provided high durability and high
breaking capacity.
XV, and XV2 Switches. DC models have also been added
to the series.
and many types of actuator are available.
easy connection.
(Ask your OMRON representative for information on
approved models.)
Enclosed Switches
ZE/ZV/ZV2/XE/XV/XV2
@@-@-2@
V2 : Diagonal side mounting
X
E
V
Z
Be sure to read Safety Precautions on page 8 to 9 and
Safety Precautions for All Limit Switches.
: SPDT (AC)
: SPDT (DC)
: Side mounting
: Base mounting
(4)
(Not all combinations are possible. Ask your OMRON representative for details.)
(3) Actuator
QA277 : One-way action roller arm lever
NA277 : Sealed one-way action roller arm lever
QA2 : Roller arm lever
Q22 : Roller plunger
Q21 : Crossroller plunger
NA2 : Sealed roller arm lever
N22 : Sealed roller plunger (ZE, ZV, ZV2 only)
N21 : Sealed crossroller plunger (ZE, ZV, ZV2 only)
Q
N
: Plunger
: Sealed plunger
(4) Conduit/Ground Terminal
None : G 1/2/without ground terminal
SG1 : 1/2-14NPSM/with ground terminal
YG1 : M20/with ground terminal
G1
G
S
Y
CSM_ZE_ZV_ZV2_XE_XV_XV2_DS_E_2_1
: G 1/2/with ground terminal
: Pg13.5/with ground terminal
: 1/2-14NPSM/without ground terminal
: M20/without ground terminal
*
1

Related parts for ZV2-NA2-2S

ZV2-NA2-2S Summary of contents

Page 1

... Diagonal side mounting N22 : Sealed roller plunger (ZE, ZV, ZV2 only) N21 : Sealed crossroller plunger (ZE, ZV, ZV2 only) NA2 : Sealed roller arm lever NA277 : Sealed one-way action roller arm lever * Consult with your OMRON representative concerning availability, pricing, and delivery of conduit sizes and ground terminal specifications other than those on standard models ...

Page 2

... ZV2-Q21-2 --- ● ● ● ZV2-QA2-2 XV2-QA2-2 ● --- ZV2-QA277-2 --- --- ● ● ● ZV2-N-2 XV2-N-2 ● ● ● ZV2-N22-2 ● ● ● ZV2-N21-2 ● ● ● ZV2-NA2-2 XV2-NA2-2 ● ● ● ZV2-NA277-2 --- XV2-NA277 max. Inrush current max. Note: 1. The above figures are for standard currents. ...

Page 3

... VAC Switching current (A) ZE/ZV/ZV2/XE/XV/XV2 IP65*1 Z@: 10,000,000 operations min. X@: 1,000,000 operations min. Z@: 500,000 operations min., for 15 A, 250 VAC resistive load X@: 100,000 operations min., for 10 A, 125 VDC resistive load Plunger type: 0.01 mm/s to 0.5 m/s Lever type: 0.02 mm/s to 0.5 m/s ...

Page 4

... XE-Q22-2 5.00 N max. 2.45 to 3.43 N 5.00 N max. 1.12 N 1.12 N 1.12 N 0.9 mm 0.5 mm 0.9 mm 5.5 mm 3.6 mm 3.6 mm 0.47 mm 0.05 mm 0.47 mm 49.7±1 mm ZE/ZV/ZV2/XE/XV/XV2 NC NO (Unit: mm) × 12.7 dia. 4.8 * JIS B0202 G1/2 Effective thread: 4 threads min. 17 Two, M4 (length: 45) 23 2.1 ± 25.4 ...

Page 5

... XE-NA2-2 ZE-NA277-2 XE-NA277-2 7.26 N 6.28 N 7.26 N 2.26 N 2. 5.5 mm 0.72 mm 0.4 mm 0.72 mm --- --- ZE/ZV/ZV2/XE/XV/XV2 12R * JIS B0202 G1/2 Effective thread: 4 threads min. 17 Two, M4 (length: 45) 23 ± 2.1 0.1 ± 25.4 0.3 24 ± 25.4 0. Stainless steel plunger × ...

Page 6

... Base Mounting/Diagonal Side Mounting Models The diagrams show the base-mounted model (ZV-@ or XV-@) on top and the diagonal side-mounted model (ZV2-@ or XV2-@) on bottom. The flange on base-mounted models is shown with dotted lines. Plunger ZV(2)-Q (ZV-Q-2/XV-Q-2 flange) XV(2)-Q-2 ± Two, 4.3 0.2 dia. ...

Page 7

... N 6. min. 1. max min 5 max. 0 --- Note for ZV2-N-2 and XV2-N-2 is 31.9 ±0.8 mm for ZV2-N22-2 is 35.7 ±0.8 mm for ZV2-N21-2 is 35.7 ±0.8 mm. Sealed Plunger ZV(2)-N-2 XV(2)-N-2 ± 41.3 0.2 54 ± 10.6 0.3 36.6 Operates in this direction only 39 ...

Page 8

... Two, 5.4 dia. 25.4 0.3 0 holes *1. Stainless sintered alloy roller *2. Adjustment between 0° to 225°. *3. Only the ZV2-NA2-2 and XV2-NA2-2 incorporate mounting holes. Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. ZV-NA2-2 XV-NA2-2 ZV2-NA2-2 XV2-NA2-2 OF max. 6. min. ...

Page 9

... The roller arm mounting bracket can be set in any direction after loosening the nut. • Make sure that the nut is free of foreign substances when the nut is loosened. • A dedicated wrench is provided separately. ZE/ZV/ZV2/XE/XV/XV2 Bottom Mounting Two, 4.3 dia. mounting holes or M4 screw holes 41.3± ...

Page 10

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords