HL-5050G Omron, HL-5050G Datasheet - Page 2

no-image

HL-5050G

Manufacturer Part Number
HL-5050G
Description
SWITCH LIMIT ADJUSTABL ROD LEVER
Manufacturer
Omron
Series
HL-5000r
Datasheet

Specifications of HL-5050G

Circuit
DPST (1-NO, 1-NC)
Switch Function
On-Mom, Off-Mom
Contact Rating @ Voltage
5A @ 125VAC
Actuator Type
Adjustable Rod
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
735gf
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
HL5050G
Characteristics
Note: 1. The above figures are initial values.
* The values are calculated at an operating temperature of +5
Structure and Nomenclature
Structure
Degree of protection
Durability
Operating speed
Operating
frequency
Insulation resistance
Contact resistance
Dielectric strength
Rated frequency
Vibration
resistance
Shock
resistance
Ambient operating
temperature
Ambient operating
humidity
Weight
an operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating environments.
2. The above characteristics may vary depending on the model. For
further details, contact your OMRON sales representative.
*
Cover
Mechanical
Electrical
Mechanical
Electrical
Malfunction
Destruction
Malfunction
IP65
10,000,000 operations min. (under
rated conditions)
See the following Electrical Durability.
5 mm/s to 0.5 m/s
120 operations/min
30 operations/min
100 MΩ min. (at 500 VDC)
25 mΩ max. (initial value)
1,000 VAC, 50/60 Hz for 1 min between
terminals of the same polarity
1,500 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and ground
1,500 VAC, 50/60 Hz for 1 min between
each terminal and non-current-carrying
metal part
50/60 Hz
10 to 55 Hz, 1.5-mm double amplitude
1,000 m/s
300 m/s
−5°C to +65°C (with no icing)
35% to 95%RH
Approx. 130 to 190 g
2
min.
2
Resin roller
Lever
Head
Built-in switch
Connector
min.
°
C to +35
°
C, and
Engineering Data
Electrical Durability (cos dia. =1)
(Operating temperature: +5°C to +35°C,
Operating humidity: 40% to 70%RH)
Contact Form
1,000
500
0
1
(NO) 4
(NC) 1
2
3
Za
Operating frequency:
30 operations/min
125 VAC (cos dia. = 1)
4
Switching current (A)
3 (NO)
2 (NC)
5
6
HL-5000
2

Related parts for HL-5050G